Contained Within
Find More Documentation
Featured Support Resources
|
Chapter 3 Solaris Installation and Configuration
Before you begin, make sure that all Solaris systems have access to the following:
-
All Perl packages (SUNWpl5*)
-
The SUNWbash package
-
All language packages
-
The management station that will be built from a puppet server
-
Port 6364 open in firewall for puppet interface
-
Port 6789 open in firewall for Storade interface
3.1 Building the Management Station
The management station is built from a server, called the puppet server, that
is originally connected to your corporate network.
To Build the Management Station
Steps
-
Obtain a copy of the management station flash archive from your Sun representative.
Save it with the following path and filename:
/export/puppet/world/archive/full-flars/standard/genericmodel
/sparc-sunos5.9/mgmt.flar
|
-
Assign a new IP address in your corporate network for the management station.
-
Add the management station's MAC address to your local /etc/ethers file.
-
Run the /export/puppet/bin/preconfig utility and
provide the following information when prompted:
Puppet Host Configuration
=========================
Main Menu:
[A]dd a new client
[D]elete clients
[L]ist clients
[M]odify a client
=========================
[Q]uit
Which one [Q]:a
Client name []:mgmt-name-01.domain
Client mac: 0:3:cd:aa:d7:21
Machine Type ("uname -m") []: sun4u
Client processor: sparc
Select a bootable image:
1: sunos_5.10_74L2a_sparc
2: sunos_5.10_b72_sparc
3: sunos_5.10_b73_sparc
4: sunos_5.9_u5cd1combined_sparc
5: sunos_5.9_u7cd1combined_sparc
Enter the number of your selection []:5
Model selection:
1: none
2: itserver59 [Meta]
3: desktop [Children]
4: sunray [Children]
5: itsunray [Meta]
6: itdesktop59-nwk [Meta]
7: itsunray30 [Meta]
8: itdesktop59 [Meta]
9: server [Children]
==================================================
[S]elect, [U]nselect, [L]ist selected, [D]escribe,
[R]eturn, [Q]uit [R]:1
1: itdesktop59-nwk [Meta]
2: server [Children]
3: itdesktop59 [Meta]
ON 4: none
5: desktop [Children]
6: itsunray [Meta]
7: itserver59 [Meta]
8: sunray [Children]
9: itsunray30 [Meta]
==================================================
[S]elect, [U]nselect, [L]ist selected, [D]escribe,
[R]eturn, [Q]uit [R]:Enter
Select a flash image:
1: nfs://server/export/puppet/world/archive/full-flars/standard/genericmodel
/sparc-sunos5.9/mgmt.flar
4: Do not use flash.
Enter the number of your selection []:1
Profile selection:
1: DEFAULT
2: LASTPROFILE
3: all+locales_04GB+_rootdisk
4: all_04GB+_rootdisk
[S]elect, [C]ustom, [V]iew, [Q]uit: [S]: c
Please select a starting profile:
1: DEFAULT
2: LASTPROFILE
3: all+locales_04GB+_rootdisk
4: all_04GB+_rootdisk
[S]elect, [R]eturn, [V]iew, [Q]uit: [S]1
Change filesystem layout only to
filesys rootdisk.s1 8192 swap
filesys rootdisk.s0 10240 / logging
filesys rootdisk.s3 1024 /home logging
filesys rootdisk.s4 free /var logging
filesys rootdisk.s5 16384 /opt logging
filesys c1t2d0s6 free /export logging
filesys rootdisk.s7 512
filesys c1t1d0s7 512
filesys c1t2d0s7 512
filesys c1t3d0s7 512
Summary for mgmt-sfbay-01:
MAC Address : 0:3:cd:aa:d7:21
Machine Type: sun4u
Boot Image : sunos_5.9_u7cd1combined_sparc
Flash Image : nfs://server/export/puppet/world/archive/full-flars/standard/
genericmodel/sparc-sunos5.9/mgmt.flar
Platform : sparc-sunos5.9
Profile : custom
Model Config: none
Correct ([Y]/N):y
Configuring mgmt-name-01....
Performing add_install_client...
cleaning up preexisting install client "mgmt-name-01"
removing mgmt-name-01 from bootparams
updating /etc/bootparams
Using /export/puppet/world/archive/os_images/sunos_5.9_u7cd1combined_sparc
/Solaris_9/Misc/jumpstart_sample/check
quickcheck: Only the rule for mgmt-name-01 will be verified.
It is assumed that the rest of the rules in /export/puppet/world/rules
are correct.
Validating /tmp/checkrules.7470...
Validating profile hostconfig/mgmt-name-01/jumpstartprofile...
/tmp/checkrules.7470.ok file not created
The custom JumpStart configuration is ok.
Puppet Host Configuration
=========================
Main Menu:
[A]dd a new client
[D]elete clients
[L]ist clients
[M]odify a client
=========================
[Q]uit
Which one [Q]:q
|
-
Run the following commands:
prtvtoc -h /dev/rdsk/c1t0d0s2 | fmthard -s - /dev/rdsk/c1t1d0s2
prtvtoc -h /dev/rdsk/c1t2d0s2 | fmthard -s - /dev/rdsk/c1t3d0s2
metadb -afc 3 /dev/dsk/c1t0d0s7 /dev/dsk/c1t1d0s7 /dev/dsk/c1t2d0s7 /dev/dsk/c1t3d0s7
metainit -f d100 1 1 c1t0d0s0
metainit -f d101 1 1 c1t0d0s1
metainit -f d103 1 1 c1t0d0s3
metainit -f d104 1 1 c1t0d0s4
metainit -f d105 1 1 c1t0d0s5
metainit -f d106 1 1 c1t2d0s6
metainit -f d0 -m d100
metainit -f d1 -m d101
metainit -f d3 -m d103
metainit -f d4 -m d104
metainit -f d5 -m d105
metainit -f d6 -m d106
metaroot d0
|
-
Edit the /etc/vfstab file and make the following
modifications:
-
Change swap to /dev/md/dsk/d1
-
Change /home to /dev/md/dsk/d3 /dev/md/rdsk/d3
-
Change /var to /dev/md/dsk/d4 /dev/md/rdsk/d4
-
Change /opt to /dev/md/dsk/d5 /dev/md/rdsk/d5
-
Change /export to /dev/md/dsk/d6 /dev/md/rdsk/d6
-
Run the following commands:
metainit -f d200 1 1 c1t1d0s0
metainit -f d201 1 1 c1t1d0s1
metainit -f d203 1 1 c1t1d0s3
metainit -f d204 1 1 c1t1d0s4
metainit -f d205 1 1 c1t1d0s5
metainit -f d206 1 1 c1t3d0s6
|
-
Reboot the management station.
-
Run the following commands:
metattach d0 d200
metattach d1 d201
metattach d3 d203
metattach d4 d204
metattach d5 d205
metattach d6 d206
sys-unconfig
|
-
Move the management station to the server network, then connect it to
the back-end (BE) and front-end (FE) networks.
-
Boot the management station and set up the default route and both BE and
FE interfaces.
Configure the management station as an NTP server for other
Edge hosts that aren't able to refer to NTP servers on the corporate network nor on
the Internet. The following is a template for /etc/inet/ntp.conf:
# NTP stratum 4 config
#
# stratum 3 (domainclock) servers nearby
#
server t3-name1.local-domain prefer
server t3-name2.domain2
server t3-name3.domain3
server t3-name4.domain4
#
# stratum 4 (timetone) local peers
#
peer t4-name1.local-domain
peer t4-name2.local-domain
peer t4-name3.local-domain
peer t4-name4.local-domain
#
# Set up for site-wide multicast with one network hop. Increase ttl
# value carefully since you can swamp other sites with multicast traffic.
#
broadcast 224.0.1.1 ttl 1
#
# This line sets up the server so that the server can not be modified
# remotely. In addition remote logging traps are disabled.
#
restrict default nomodify notrap
#
# This re-enables all functions locally so that you can change stuff
# locally on the fly.
#
restrict 127.0.0.1
#
enable monitor
driftfile /var/ntp/ntp.drift
statsdir /var/ntp/ntpstats/
filegen peerstats file peerstats type day enable
filegen loopstats file loopstats type day enable
#
# Clockstats is only needed if a reference clock is attached to the server.
#filegen clockstats file clockstats type day enable.
|
-
Once /etc/inet/ntp.conf is modified, restart xntpd with the following commands to enable the new configuration:
# /etc/init.d/xntpd stop; /etc/init.d/xntpd start
|
-
Check /var/adm/messages with the following command
to see if the process has started without problems:
# grep ntp /var/adm/messages
|
3.2 Jump-Starting the Servers
Use the following procedures to prepare for jump-starting the servers and configuring
them afterwards. Jump-starting a server reinstalls the operating system and file system
on a server, obliterating any old files. Before you begin, create a list of all servers
with their MAC address, IP address and hostname for each one. Group the servers in
the following categories:
Then initialize the management station as follows:
For each server, you must perform the following preparation according to the
server category, and you must jump-start the server before configuring the next one.
The configuration of the server afterwards may be performed immediately after jump-starting
or after all servers have been jump-started.
To Prepare and Jump-Start a Server
Steps
-
Log into the puppet web interface at https://puppetServer.domain:6364/config.
-
Select the Advanced Client link. On the Advanced Client page, enter the
hostname of the server to jump-start, and press Enter. The server's MAC address should
automatically be entered in the Ethernet Address field. Fill in the other fields as
follows:
-
Machine Type: sun4u
-
Boot Image: sparc-sunos5.9_u7
-
Model Configuration: for a BE server, select PSC_META,
for all others select FE_PSC_META
Click Add when all fields are complete.
-
Click on Update Screen, and then on Verify Configuration. In the next
screen, click on Commit Changes, and then on Go Back.
-
Under Base Jumpstart Profile, select the profile corresponding to the
type of server:
-
For a BE server, select req_BE+_rootdisk
-
For a FE server, select req_FE+_rootdisk
-
For a FEMTA server, select req_FEMTA+_rootdisk
-
For the administration station, select all_AW+_rootdisk
-
For the backup server, select req_BACKUP+_rootdisk
-
Make sure the sysidbase value is set to DEFAULT.
-
Click on Verify Configuration, then on Commit Changes. Now click Go Back
and Fetch Current Configuration.
-
Review the profile and if everything is correct, click on Verify Configuration.
The next screen will reconfirm the information, with different models for different
server types:
Hostname serverName
Ethernet Address 0:3:cd:aa:d7:21
Boot Method bootp
Puppet Platform sparc-sunos5.9
Install Image sparc-sunos5.9_u7
Picked Models PSC_META
Expanded Models server server:std-server200501 std-server200501:psc-JES-
model200501 std-server200501:psc-cluster-model200501 std-server200501:psc-
model200501 std-server200501:psc-vts200501 std-server200501:san44-model200501
SunOS: Profile req_BE+_rootdisk
SunOS: sysidcfg(s)
base: DEFAULT
|
-
Click Commit Changes one last time and verify that there are no errors
in the configuration. The next screen summarized the actions of the configurator:
Puppet: Begin Installation Configuration
* Puppet: Client configuration written
* SunOS: profile written.
* SunOS: sysidcfg written.
* SunOS: bootenv.rc written.
* SunOS: rules written.
* SunOS: SI_CONFIG_DIR/rules re-built.
* SunOS: passed quickcheck.
* Puppet: OS Driver passed
Puppet: End Installation Configuration
|
-
Connect to the console port of the server to be jump-started and enter
the following command:
-
After the server has rebooted, follow the configuration procedure for
the type of server:
To Configure a BE Server After Jump-Start
Steps
-
Edit the prompt in the /.profile for root:
PS1="`tput bold``/usr/ucb/whoami`@`uname -n`:#`tput sgr0` "
|
-
Restore the contents of /var/bits with the following
commands:
# cd /var
# gzcat bits/bits.tar.gz | tar xf -
|
-
Change ownership of home directories with the following commands:
# cd /home
# for I in `ls`
> do
> chown $I $I
> done
# cd /
|
-
Once the system is on the corporate network, edit /etc/passwd and /etc/user_attr to put root back as a role.
-
Add the cluster to the path:
PATH=/usr/bin:/usr/sbin:/usr/ucb:/usr/ccs/bin:/usr/cluster/bin:$PATH
|
Also, add the cluster to the path in the /.cshrc file for root:
set path=( /usr/bin /usr/sbin /usr/ccs/bin /usr/cluster/bin $path )
|
-
Create additional metadbs with the following command:
metadb -a -c 3 /dev/dsk/c1t1d0s7 /dev/dsk/c1t2d0s7 /dev/dsk/c1t3d0s7
|
-
Create mirrors of /globaldevices and /var/crash. This requires several commands, some of which depend on which node of
the cluster the server belongs to.
-
Unmount the file systems with the following commands:
-
On all servers regardless of cluster node:
umount /globaldevices
umount /var/crash
newfs -v -i 1024 /dev/rdsk/c1t0d0s3
metainit -f d106 1 1 c1t2d0s0
metainit -f d206 1 1 c1t3d0s0
metainit -f d6 -m d106
|
-
On servers in cluster node 1:
metainit -f d103 1 1 c1t0d0s3
metainit -f d203 1 1 c1t1d0s3
metainit -f d3 -m d103
|
-
On servers in cluster node 2:
metainit -f d113 1 1 c1t0d0s3
metainit -f d213 1 1 c1t1d0s3
metainit -f d13 -m d113
|
-
Then edit the /etc/vfstab file:
-
On all servers regardless of cluster node, comment out the entries for
/globaldevices and /var/crash. Then add the following line:
/dev/md/dsk/d6 /dev/md/rdsk/d6 /var/crash ufs 2 yes logging
|
-
On servers in cluster node 1, add the following line:
/dev/md/dsk/d3 /dev/md/rdsk/d3 /globaldevices ufs 2
|
-
On servers in cluster node 2, add the following line:
/dev/md/dsk/d13 /dev/md/rdsk/d13 /globaldevices ufs 2 yes logging
|
-
Attach the submirrors with the following commands:
-
On all servers regardless of cluster node:
mount /globaldevices
mount /var/crash
metattach d0 d200
metattach d6 d206
|
-
On servers in cluster node 1:
-
On servers in cluster node 2:
Example 3–1 File System Layout of BE Servers
The BE servers are V440 machines with 2 available disks of 73 GB each.
|
Partition Name
|
Size
|
Raid
|
Description
|
|
/
|
10 GB
|
Mirror
|
Root file system
|
|
/opt
|
30 GB
|
Mirror
|
AllJava ESinstalled component binaries (LDAP, messaging, portal, calendar,
identity).
|
|
/var
|
30 GB
|
|
Log file system
|
|
/swap
|
4 GB
|
Disk 3
|
Memory tmp file system
|
|
Dump Device
|
|
Disk 4
|
Core dump filesystem
|
|
/shared/bedgeN/cal/backup
|
20 GB
|
|
Mount point
|
|
/shared/bedgeN/cal/db
|
20 GB
|
|
Mount point
|
|
/shared/bedgeN/msg/conf
|
5 GB
|
|
Mount point (soft partition)
|
|
/shared/bedgeN/msg/imta
|
15 GB
|
|
Mount point (soft partition)
|
|
/shared/bedgeN/msg/imta/db
|
|
|
|
|
/shared/bedgeN/msg/imta/queue
|
|
|
|
|
/shared/bedgeN/partition/ store###
|
180 or 230 GB
|
|
Mount point
|
|
/shared/bedgeN/var
|
5 GB
|
|
Mount point
|
|
/shared/bedgeN/var/log
|
|
|
|
|
/shared/bedgeN/var/backup
|
|
|
|
|
/shared/bedgeN/dbbackup
|
15 GB
|
|
Mount point
|
To Configure a FE or Backup Server After Jump-Start
Steps
-
Edit the prompt in the /.profile for root:
PS1="`tput bold``/usr/ucb/whoami`@`uname -n`:#`tput sgr0` "
|
-
Restore the contents of /var/bits with the following
commands:
# cd /var
# gzcat bits/bits.tar.gz | tar xf -
|
-
Change ownership of home directories with the following commands:
# cd /home
# for I in `ls`
> do
> chown $I $I
> done
# cd /
|
-
Once the system is on the corporate network, edit /etc/passwd and /etc/user_attr to put root back as a role.
-
Create an additional metadb with the following command:
metadb -a -c 3 /dev/dsk/c1t1d0s7
|
-
Attach the roots mirror:
-
Set up NTP using appropriate NTP server for FE/Domain1 nodes.
-
Set up DNS using appropriate DNS servers for FE/Domain1 nodes.
-
Do a preliminary sendmail configuration using MODE="" and stopping then restarting sendmail. You will
need to re-verify this once the FE/Domain1 nodes are fully configured to be sure that root and cron mail is being delivered properly.
-
Remove the metacheck entry from the cron table,
or else put in place a valid metacheck script.
-
Fix the holidays files on all nodes in the /etc/acct/holidays file to be accurate for the current year.
Example 3–2 File System Layout of FE Servers
The FE servers are V210 machines with 2 available disks of 73 GB each.
|
Partition Name
|
Size
|
Description
|
|
/
|
14 GB
|
Root file system
|
|
/opt
|
20 GB
|
Where all Java EScomponent binaries (LDAP, messaging, portal, calendar,
identity) are installed.
|
|
/var
|
20 GB
|
Log file system
|
|
/swap
|
20 GB
|
Memory tmp file system
|
To Configure a FE-MTA After Jump-Start
Steps
-
Edit the prompt in the /.profile for root:
PS1="`tput bold``/usr/ucb/whoami`@`uname -n`:#`tput sgr0` "
|
-
Restore the contents of /var/bits with the following
commands:
# cd /var
# gzcat bits/bits.tar.gz | tar xf -
|
-
Change ownership of home directories with the following commands:
# cd /home
# for I in `ls`
> do
> chown $I $I
> done
# cd /
|
-
Once the system is on the corporate network, edit /etc/passwd and /etc/user_attr to put root back as a role.
-
Create additional metadbs with the following command:
metadb -a -c 3 /dev/dsk/c1t1d0s7 /dev/dsk/c1t2d0s7 /dev/dsk/c1t3d0s7
|
-
Re-create the mirror of /queue with striped disks:
-
Unmount it first with the following commands:
umount /queue
rm -r /queue
mkdir /imta
|
-
Set up slice3 on disks 3 & 4 using format with a start cylinder of 4226 and size of 3678 cylinders. The result should
look like the following
Total disk cylinders available: 14087 + 2 (reserved cylinders)
Part Tag Flag Cylinders Size Blocks
0 unassigned wm 0 0 (0/0/0) 0
1 swap wu 0 - 4121 20.00GB (4122/0/0) 41945472
2 backup wm 0 - 14086 68.35GB (14087/0/0) 143349312
3 unassigned wm 4226 - 7903 17.85GB (3678/0/0) 37427328
4 unassigned wm 0 0 (0/0/0) 0
5 unassigned wm 0 0 (0/0/0) 0
6 unassigned wm 0 0 (0/0/0) 0
7 unassigned wm 4122 - 4225 516.75MB (104/0/0) 1058304
|
-
Run the following command:
metainit -f d103 1 2 c1t0d0s3 c1t1d0s3 -i 32b
metainit -f d203 1 2 c1t2d0s3 c1t3d0s3 -i 32b
metainit -f d3 -m d103
newfs -m 2 -i 4096 -o time /dev/md/rdsk/d3
|
-
Edit the /etc/vfstab file. Comment out the following
line:
/dev/dsk/c1t0d0s3 /dev/rdsk/c1t0d0s3 /queue ufs 2 yes
logging
|
Add the following line:
/dev/md/dsk/d3 /dev/md/rdsk/d3 /imta ufs 2 yes logging
|
-
Run the following command:
mount /imta
metattach d0 d200
metattach d3 d203
|
-
Set up NTP using appropriate NTP server for FE/Domain1 nodes.
-
Set up DNS using appropriate DNS servers for FE/Domain1 nodes.
-
Do a preliminary sendmail configuration using MODE="" and stopping then restarting sendmail. You will
need to re-verify this once the FE/Domain1 nodes are fully configured to be sure that root and cron mail is being delivered properly.
-
Remove the metacheck entry from the cron table, or else put in place a valid metacheck script.
-
Fix the holidays files on all nodes in the /etc/acct/holidays file to be accurate for the current year.
Example 3–3 File System Layout of FE Servers
The FE MTA servers are V240 machines with 4available disks of 73 GB each.
|
Partition Name
|
Size
|
Description
|
|
/
|
10 GB
|
Root file system
|
|
/opt
|
20 GB
|
Where all Java EScomponent binaries (LDAP, messaging, portal, calendar,
identity) are installed.
|
|
/var
|
20 GB
|
Log file system
|
|
/swap
|
20 GB
|
Disk 3: memory temp file system
|
|
/queue
|
16 GB
|
Stripe of 4 disks (4x4) for MTA queues
|
To Configure the Administration Station After Jump-Start
Steps
-
Edit the prompt in the /.profile for root:
PS1="`tput bold``/usr/ucb/whoami`@`uname -n`:#`tput sgr0` "
|
-
Restore the contents of /var/bits with the following
commands:
# cd /var
# gzcat bits/bits.tar.gz | tar xf -
|
-
Change ownership of home directories with the following commands:
# cd /home
# for I in `ls`
> do
> chown $I $I
> done
# cd /
|
-
Once the system is on the corporate network, edit /etc/passwd and /etc/user_attr to put root back as a role.
-
Create additional metadbs with the following command:
metadb -a -c 3 /dev/dsk/c1t1d0s7 /dev/dsk/c1t2d0s7 /dev/dsk/c1t3d0s7
|
-
Create a mirror of /export:
-
Unmount it first with the following command:
umount /export
metainit -f d106 1 1 c1t2d0s6
metainit -f d206 1 1 c1t3d0s6
metainit -f d6 -m d106
|
-
Edit the /etc/vfstab file. Comment out the entry
for /export and add the following line:
/dev/md/dsk/d6 /dev/md/rdsk/d6 /export ufs 2 yes logging
|
-
Remount and attach the submirrors with the following commands:
mount /export
metattach d0 d200
metattach d6 d206
|
3.3 Network and System Tuning
The following procedure adjusts some network and system settings to optimize
performance.
To Optimize Network and System Settings
Steps
-
Setup coreadm with the following commands:
mkdir -p /var/crash/cores
coreadm -g /var/crash/cores/%f.%n.%p.core -e global -e global-setid -e log
-i /var/crash/cores/core.%f.%p.%n.%u.%g.%t -e process -e proc-setid
|
-
Setup a cron job to regularly purge old core files:
0 5 * * * find /var/crash/cores -mtime +7 -type f -exec rm {} \;
|
-
Make sure the /etc/hosts file contain hostname resolutions
of all BE and FE servers:
set ncsize=4194304
set ufs_ninode=8388608
|
-
Tune the network settings for LDAP access on the servers in the mail clusters:
ndd -set /dev/tcp tcp_conn_req_max_q 4096
ndd -set /dev/tcp tcp_keepalive_interval 600000
ndd -set /dev/tcp tcp_ip_abort_cinterval 10000
ndd -set /dev/tcp tcp_ip_abort_interval 60000
|
Make these changes permanent by adding the above four configuration commands
to the bottom of the /etc/init.d/inetinit file.
-
If desired, run the Sun Security Weakness Attack Tool (SunSWAT) to audit
network vulnerabilities:
/opt/NSGswat/bin/sunswat -s isss
|
|