Appendix A Alternate Sun Fire
V20z and V40z Reference Configuration
Sun Fire V20z and V40z servers have two management ports, SP0 and SP1,
as shown by the following logical port diagram.

The Sun Fire V20z and V40z servers can be connected to a switch in either
of two ways:
-
Direct connections:
The SP0 port of each server
connects directly to the switch for the management network. Therefore, the
switch must have a 1–Mbit port for each server.
-
Daisy-chaining:
-
The SP0 port of the first server must be connected
to the switch.
-
The SP1 port of the first server must be connected
to the SP0 port of the second server.
-
The SP1 port of the second server must be
connected to the SP0 port of the third server and so on.
Tip –
To ensure performance, daisy-chain up to five Sun Fire V20z and
V40z architecture machines. If you have more than five Sun Fire V20z or V40z
management port machines, daisy-chain the machines in clusters of five.
Therefore, the switch needs only one 1–Mbit port for each group
of five Sun Fire V20z and V40z servers.
The following figure illustrates a Sun Fire V20z and V40z daisy-chained
configuration.
Figure A–1 Five Daisy-Chained SP Manageable Servers, One Switch