TABLE D-1
Rule
Number..Description

Action
General: syrules.tcl
0....Symond statusalarm, snmp
1....Server statusalarm, snmp
3....Log Scanner statusalarm, snmp
4....Kernel Reader statusalarm, snmp
6....Delay initial Log Scanner and death statusnone
7....Delay initial Kernel Reader death status

8....Warning if label contains "."

none
9....Warning if label contains "*"alarm, snmp
General: egrules.tcl
TABLE D-1 (Continued)
Rule
Number..Description

Action
50....Trim event log if getting fullalarm, snmp
52....Warning when ls_hist is corruptedalarm, snmp
53....Warning on incorrect Tcl rule syntaxalarm, snmp
General: swrules.tcl
100...Disk busyalarm, snmp
102...Swap spacealarm, snmp
103...CPU swapping and pagingalarm, snmp
104...CPU loadalarm, snmp
105...File system fullalarm, snmp
106...No swap spacealarm, snmp
General: hwrules.tcl
209...SIMM erroralarm, snmp
210...ssd hardware erroralarm, snmp
211...ssd fatal erroralarm, snmp
212...SIMM erroralarm, snmp
214...configd.*.status failingalarm, snmp
216...CPU panicalarm, snmp
217...Tape error rate highalarm, snmp
219...ssd off-linealarm, snmp
220...ssd okay (online)alarm, snmp
222...Fatal SunVTS erroralarm, snmp
223...SunVTS erroralarm, snmp
General: pfrules.tcl
300...SIMM errorsadd_pfa SIMM
301...Disk soft errorsadd_pfa DISK
302...Disk soft errors from smart drivesalarm, snmp
303...Check SIMM (test period 1)alarm, snmp
304...Check SIMM (test period 2)alarm, snmp
305...Check SIMM (test period 3)alarm, snmp
306...Check disk pfa (warning)alarm, snmp
TABLE D-1 (Continued)
Rule
Number..Description

Action
307...Check disk pfa (severe)alarm, snmp
308...Trims pfa historynone
General: cprules.tcl
400...CPU overload over x hoursalarm, snmp, add_cpa
401...Disk busy over x hoursalarm, snmp, add_cpa
402...Swap space low over x hoursalarm, snmp, add_cpa
403...Meta CPU events (check_cpa_cpu)alarm, snmp
404...Meta disk events (check_cpa_disk)alarm, snmp
405...Meta swap events (check_cpa_swap)

406...Trims cpa history

407...Initializes timestamp for rules 400 and 402

alarm, snmp
Platform-Specific Rules: SPARCserver 1000(E), SPARCcenter 2000(E ) -
SS1000.tcl, SC2000.tcl
1002...Config Reader statusalarm, snmp
1005...Delay initial Config Reader death statusnone
1207...system.*.*.*.statusalarm, snmp
1208...system.*.*.*.*.*.*.statusalarm, snmp
1224a..system.*.*.*.*.*.*.*.statusalarm, snmp
1225...Corrected ECC error

1230a..Sun StorEdge A3000 (formerly RSM Array 2000) controller and disk status; matches system.*.*.*.*.*.*.*.*.status

alarm. snmp
Platform-Specific Rules: Sun Enterprise 450: UE450.tcl
1002...Config Reader statusalarm, snmp
1005...Delay initial configd death statusnone
1204...system.*.fan.statusalarm, snmp
1205...system.*.*.*.temperaturealarm, snmp, mailto
1207...system.*.*.*.statusalarm, snmp
TABLE D-1 (Continued)
Rule
Number..Description

Action
1208...system.*.*.st.statusalarm, snmp
1212...system.power-supply.statealarm, snmp
1213...system.power-supply.limitalarm, snmp
1214...system.power-supply.current-sharealarm, snmp
1215...system.power-supply.temperaturealarm, snmp, mailto
1224...system.*.*.*.*.*.*.*.statusalarm, snmp
1226...system.system-board.*.mc.bank.statusalarm, snmp
1227...system.system-board.*.mc.bank.dimm.statusalarm, snmp
Platform-Specific Rules: Sun Enterprise 250 UE250.tcl
1002...Config Reader statusalarm, snmp
1005...Delay initial configd death statusnone
1204...system.cpu-fans.status.statusalarm, snmp
1205...system.system-board.*.cpu-unit.temperaturealarm, snmp, mailto
1207...system.*.*.*.statusalarm, snmp
1208...system.*.*.st.statusalarm, snmp
1212...system.power-supply.statealarm, snmp
1224...system.*.*.*.*.*.*.*.statusalarm, snmp
1226...system.system-board.*.mc.bank.statusalarm, snmp
1227...system.system-board.*.mc.bank.dimm.statusalarm, snmp
Platform-Specific Rules: Sun Enterprise 3x00 -6x00: UEnterprise.tcl
1002...Config Reader statusalarm, snmp
1005...Delay initial Config Reader death statusnone
1201...Hot plug charge DC statusalarm, snmp
1202...Hot plug precharge DC statusalarm, snmp
1203...system.*.statusalarm, snmp
1204...Fan statusalarm, snmp
TABLE D-1 Default Solstice SyMON Rules (Continued)

 Rule  
 Number      Description                             Action  


1205 CPU board temperature alarm, snmp, mailto 1206 I/O and clock board temperature alarm, snmp, mailto 1207 system.*.*.*.status alarm, snmp 1208 system.*.*.*.*.*.status alarm, snmp 1209 system.*.*.*.*.*.*.status alarm, snmp 1213 Hot plug "removed" alarm, snmp 1215 Hot plug "hotplugged into" alarm, snmp 1218 system.*.*.*.*.status alarm, snmp 1219 AC status 1220 Hot plug "installed" alarm, snmp 1221 Redundant power status alarm, snmp 1230 Sun StorEdge A3000 (formerly RSM Array 2000) controller and disk status; matches system.*.*.*.*.*.*.*.status
Platform-Specific Rules: Sun Enterprise 150: UEnterpriseI.tcl 1002 Config Reader status alarm, snmp 1005 Delay initial configd death status none 1207 system.*.*.*.status alarm, snmp 1208 system.*.*.*.*.*.*.status alarm, snmp
Storage-Specific Rules: Sun StorEdge A5000 (formerly Sun Enterprise Network Array): SENA.tcl 5010 Backplanes; SES data to test for alarm, snmp status=critical 5011 Interconnect failure; SES data to test foralarm, snmp EPROM failure 5012 Disk slots; SES data to test for over alarm, snmp temperature warning or failure for front disks 5013 Disk slots; SES data to test for under alarm, snmp temperature warning or failure for rear disks
TABLE D-1 (Continued)
Rule
Number..Description

Action
5020...Disk slots; SES data to test for fault or fault requested (front disks)alarm, snmp
5021...Disk slots; SES data to test for fault or fault requested (rear disks)alarm, snmp
5030...Gigabit Interface Converter (GBIC)*; SES data to test for transmit failurealarm, snmp
5035...Interface boards; SES data to test for over temperaturealarm, snmp
5037...Interface boards; SES data to test for loop 0 faultalarm, snmp
5038...Interface boards; SES data to test for loop 1 faultalarm, snmp
5040...Power supplies; SES data to test for over temperature warning or failurealarm, snmp
5045...Power supplies; SES data to test for DC under or over voltagealarm, snmp
5047...Power supplies; SES data to test for DC over currentalarm, snmp
5049...Power supplies; SES data to test for AC failurealarm, snmp
5060...Fan trays; SES data to test for fan failurealarm, snmp