- APPENDIX D
Default Solstice SyMON Rules
- This appendix describes the default rules for this release of Solstice SyMON. Use this appendix to determine the rules that are incorporated into this Solstice SyMON release. By identifying the default rules, you can determine whether or not you need to write a new rule.
-
Note - The sample.tcl file in Solstice SyMON 1.1 through 1.3 contained only a comment.
-
TABLE D-1 describes the default rules supplied with this release of Solstice SyMON. The columns in the table describe the following:
-
- Column 1 is the rule number.
- Column 2 is a description of the rule.
- Column 3 is the action taken when the condition is true.
-
TABLE D-1
Rule
Number..Description |
Action |
| General: syrules.tcl |
|
| 0....Symond status | alarm, snmp |
| 1....Server status | alarm, snmp |
| 3....Log Scanner status | alarm, snmp |
| 4....Kernel Reader status | alarm, snmp |
| 6....Delay initial Log Scanner and death status | none |
| 7....Delay initial Kernel Reader death status 8....Warning if label contains "."
| none |
| 9....Warning if label contains "*" | alarm, snmp |
| General: egrules.tcl |
|
-
TABLE D-1 (Continued)
Rule
Number..Description |
Action |
| 50....Trim event log if getting full | alarm, snmp |
| 52....Warning when ls_hist is corrupted | alarm, snmp |
| 53....Warning on incorrect Tcl rule syntax | alarm, snmp |
| General: swrules.tcl |
|
| 100...Disk busy | alarm, snmp |
| 102...Swap space | alarm, snmp |
| 103...CPU swapping and paging | alarm, snmp |
| 104...CPU load | alarm, snmp |
| 105...File system full | alarm, snmp |
| 106...No swap space | alarm, snmp |
| General: hwrules.tcl |
|
| 209...SIMM error | alarm, snmp |
| 210...ssd hardware error | alarm, snmp |
| 211...ssd fatal error | alarm, snmp |
| 212...SIMM error | alarm, snmp |
| 214...configd.*.status failing | alarm, snmp |
| 216...CPU panic | alarm, snmp |
| 217...Tape error rate high | alarm, snmp |
| 219...ssd off-line | alarm, snmp |
| 220...ssd okay (online) | alarm, snmp |
| 222...Fatal SunVTS error | alarm, snmp |
| 223...SunVTS error | alarm, snmp |
| General: pfrules.tcl |
|
| 300...SIMM errors | add_pfa SIMM |
| 301...Disk soft errors | add_pfa DISK |
| 302...Disk soft errors from smart drives | alarm, snmp |
| 303...Check SIMM (test period 1) | alarm, snmp |
| 304...Check SIMM (test period 2) | alarm, snmp |
| 305...Check SIMM (test period 3) | alarm, snmp |
| 306...Check disk pfa (warning) | alarm, snmp |
-
TABLE D-1 (Continued)
Rule
Number..Description |
Action |
| 307...Check disk pfa (severe) | alarm, snmp |
| 308...Trims pfa history | none |
| General: cprules.tcl |
|
| 400...CPU overload over x hours | alarm, snmp, add_cpa |
| 401...Disk busy over x hours | alarm, snmp, add_cpa |
| 402...Swap space low over x hours | alarm, snmp, add_cpa |
| 403...Meta CPU events (check_cpa_cpu) | alarm, snmp |
| 404...Meta disk events (check_cpa_disk) | alarm, snmp |
| 405...Meta swap events (check_cpa_swap) 406...Trims cpa history 407...Initializes timestamp for rules 400 and 402
| alarm, snmp |
Platform-Specific Rules: SPARCserver 1000(E), SPARCcenter 2000(E ) -
SS1000.tcl, SC2000.tcl |
| 1002...Config Reader status | alarm, snmp |
| 1005...Delay initial Config Reader death status | none |
| 1207...system.*.*.*.status | alarm, snmp |
| 1208...system.*.*.*.*.*.*.status | alarm, snmp |
| 1224a..system.*.*.*.*.*.*.*.status | alarm, snmp |
| 1225...Corrected ECC error 1230a..Sun StorEdge A3000 (formerly RSM Array 2000) controller and disk status; matches system.*.*.*.*.*.*.*.*.status
| alarm. snmp |
| Platform-Specific Rules: Sun Enterprise 450: UE450.tcl |
|
| 1002...Config Reader status | alarm, snmp |
| 1005...Delay initial configd death status | none |
| 1204...system.*.fan.status | alarm, snmp |
| 1205...system.*.*.*.temperature | alarm, snmp, mailto |
| 1207...system.*.*.*.status | alarm, snmp |
-
TABLE D-1 (Continued)
Rule
Number..Description |
Action |
| 1208...system.*.*.st.status | alarm, snmp |
| 1212...system.power-supply.state | alarm, snmp |
| 1213...system.power-supply.limit | alarm, snmp |
| 1214...system.power-supply.current-share | alarm, snmp |
| 1215...system.power-supply.temperature | alarm, snmp, mailto |
| 1224...system.*.*.*.*.*.*.*.status | alarm, snmp |
| 1226...system.system-board.*.mc.bank.status | alarm, snmp |
| 1227...system.system-board.*.mc.bank.dimm.status | alarm, snmp |
| Platform-Specific Rules: Sun Enterprise 250 UE250.tcl |
|
| 1002...Config Reader status | alarm, snmp |
| 1005...Delay initial configd death status | none |
| 1204...system.cpu-fans.status.status | alarm, snmp |
| 1205...system.system-board.*.cpu-unit.temperature | alarm, snmp, mailto |
| 1207...system.*.*.*.status | alarm, snmp |
| 1208...system.*.*.st.status | alarm, snmp |
| 1212...system.power-supply.state | alarm, snmp |
| 1224...system.*.*.*.*.*.*.*.status | alarm, snmp |
| 1226...system.system-board.*.mc.bank.status | alarm, snmp |
| 1227...system.system-board.*.mc.bank.dimm.status | alarm, snmp |
| Platform-Specific Rules: Sun Enterprise 3x00 -6x00: UEnterprise.tcl |
| 1002...Config Reader status | alarm, snmp |
| 1005...Delay initial Config Reader death status | none |
| 1201...Hot plug charge DC status | alarm, snmp |
| 1202...Hot plug precharge DC status | alarm, snmp |
| 1203...system.*.status | alarm, snmp |
| 1204...Fan status | alarm, snmp |
-
TABLE D-1 Default Solstice SyMON Rules (Continued)
-
Rule
Number Description Action
1205 CPU board temperature alarm, snmp,
mailto
1206 I/O and clock board temperature alarm, snmp,
mailto
1207 system.*.*.*.status alarm, snmp
1208 system.*.*.*.*.*.status alarm, snmp
1209 system.*.*.*.*.*.*.status alarm, snmp
1213 Hot plug "removed" alarm, snmp
1215 Hot plug "hotplugged into" alarm, snmp
1218 system.*.*.*.*.status alarm, snmp
1219 AC status
1220 Hot plug "installed" alarm, snmp
1221 Redundant power status alarm, snmp
1230 Sun StorEdge A3000 (formerly RSM Array
2000) controller and disk status; matches
system.*.*.*.*.*.*.*.status
Platform-Specific Rules: Sun Enterprise 150: UEnterpriseI.tcl
1002 Config Reader status alarm, snmp
1005 Delay initial configd death status none
1207 system.*.*.*.status alarm, snmp
1208 system.*.*.*.*.*.*.status alarm, snmp
Storage-Specific Rules: Sun StorEdge A5000 (formerly Sun Enterprise Network
Array): SENA.tcl
5010 Backplanes; SES data to test for alarm, snmp
status=critical
5011 Interconnect failure; SES data to test foralarm, snmp
EPROM failure
5012 Disk slots; SES data to test for over alarm, snmp
temperature warning or failure for front disks
5013 Disk slots; SES data to test for under alarm, snmp
temperature warning or failure for rear disks
|
-
TABLE D-1 (Continued)
Rule
Number..Description |
Action |
| 5020...Disk slots; SES data to test for fault or fault requested (front disks) | alarm, snmp |
| 5021...Disk slots; SES data to test for fault or fault requested (rear disks) | alarm, snmp |
| 5030...Gigabit Interface Converter (GBIC)*; SES data to test for transmit failure | alarm, snmp |
| 5035...Interface boards; SES data to test for over temperature | alarm, snmp |
| 5037...Interface boards; SES data to test for loop 0 fault | alarm, snmp |
| 5038...Interface boards; SES data to test for loop 1 fault | alarm, snmp |
| 5040...Power supplies; SES data to test for over temperature warning or failure | alarm, snmp |
| 5045...Power supplies; SES data to test for DC under or over voltage | alarm, snmp |
| 5047...Power supplies; SES data to test for DC over current | alarm, snmp |
| 5049...Power supplies; SES data to test for AC failure | alarm, snmp |
| 5060...Fan trays; SES data to test for fan failure | alarm, snmp |
| * GBIC (see Rule 5030) is a plug in module that converts signals from a fibre optic cable to work with the host adapter card. |
|