Platform Notes: Sun Enterprise 6x00/5x00/4x00/3x00 Systems
この本のみを検索
この本を見る:
PDF 文書ファイルをダウンロードする (187 KB)

Chapter 1 OpenBoot Commands

This chapter describes the OpenBoot(TM) commands for Sun Enterprise 6x00/5x00/4x00/3x00 servers.

Environmental Monitoring

The following commands are used for environmental monitoring:

Table 1-1 Environmental Monitoring Commands

Command

Usage

Purpose

disable-environmental-monitor

disable-environmental-monitor ( -- )

To stop monitoring power supply status, board temperatures, and board hot plug while the screen displays the ok prompt.

enable-environmental-monitor

enable-environmental-monitor ( -- )

To start monitoring power supply status, board temperatures, and board hot plug while the screen displays the ok prompt.

Externally Initiated Reset XIR

If a hard failure occurs, use XIR to reset the system and get information about the system state at the time of the hard failure.

To Initiate an XIR
  1. Use either the XIR button on the clock board or the remote console XIR sequence.

    When an XIR occurs, memory is cleared but some CPU state is saved.

To Display this XIR Information
  1. Type the following command at the ok prompt immediately after the XIR:


    ok .xir-state-all
    

    The output displays the CPU state for each CPU:

    #1 ok .xir-state-all
    TL=1 TT=3
    CPU ID#1
    TPC=e0028688 TnPC=e0028688 TSTATE=9900001e06
    CPU ID#5
    TL=1 TT=3
    TPC=e002755c TnPC=e0027560 TSTATE=4477001e03
    #1 ok .xir-state-all
    TL=1 TT=3


Note -

The XIR does not override the NVRAM auto-boot? variable.


Where:

TL

Trap level

TT

Trap type

TPC

Trap program counter

TStateTrap state

Hardware Watchdog

The Sun Enterprise xx00 family of servers provide the ability to enable a hardware timer that will hard-reset the system if it times out. To enable the use of this feature, watchdog_enable must be set to 1 in /etc/system.

Flash PROM Management

The following OpenBoot 3.x commands are used in flash PROM management:

Table 1-2 Environmental Monitoring Commands

Command

Usage

Purpose

flash-update-system

flash-update-system ( -- )

To download the default flash images on all the boards in the system.

prom-copy

prom-copy ( src dst -- )

To copy a flash PROM from board src to board dst. Source (src) and Destination (dst) are specified by slot number.

update-proms

update-proms ( -- )

To synchronize the latest copy of each type of PROM on all other boards of the same type.

System Configuration and Diagnostic Information

To print system configuration and diagnostic information, use prtdiag instead of using an OpenBoot command. The diagnostic information displayed lists the failed field-replaceable units (FRUs) in the system. For more information on prtdiag, see the prtdiag man page.

prtdiag(1M) Options

-v lists the most recent AC Power failure, the most recent hardware fatal error information, and, if applicable, environmental status.

-l logs its output to syslogd(1M) only if failures or errors exist in the system.

TOD Clock Management

The following commands are used for time-of-day (TOD) clock management, which includes NVRAM.

Table 1-3 Environmental Monitoring Commands

Command

Usage

Purpose

copy-clock-tod-to-io-boards

flash-update-system ( -- )

To download the default flash images on all the boards in the system.

prom-copy

prom-copy ( src dst -- )

To copy a flash PROM from board src to board dst. Source (src) and Destination (dst) are specified by slot number.

update-proms

update-proms ( -- )

To synchronize the latest copy of each type of PROM on all other boards of the same type.

Specific NVRAM Variables

The following table lists specific NVRAM variables and their values::

Table 1-4 Specific NVRAM Variables

Variable Name

Value

Default Value

configuration-policy

component

component

disabled-board-list

memory-interleave

max

max

sbus-probe-default

d3120

N/A

sbus-specific-probe

1:d120

N/A