6003
|
data
miscompare, cnt = number,
exp = value, obs = value,
receive device = name,
source device = name,
baud rate = value
|
System load too heavy for selected baud rate.
|
Reduce the system load.
|
|
Loopback connection defective.
|
Lower the baud rate.
|
|
Bad serial port hardware.
|
Check loopback connection.
|
|
System software error.
|
If the problem persists, contact your authorized Sun service provider.
|
|
6011
|
name:
packet read failed, error = error_message,
speed = number
|
System load too heavy.
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Check loopback connection.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error.
|
|
6012
|
name:
packet write failed, error = error_message,
speed = number
|
System load too heavy.
|
Reduce the system load.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error
|
|
6013
|
Device
'device_name' not responding.
No data detected after number seconds.
Received number bytes
out of number sent. Baud
rate = number
|
System load too heavy for selected baud rate.
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Lower the baud rate.
|
|
Bad serial port hardware.
|
Check the loopback connection.
|
|
System software error.
|
If the problem persists, contact your authorized Sun service provider.
|
|
6014
|
name:
expected text got text
|
|
|
|
6015
|
Incomplete
write on Port name,
len number should be number,
speed = number
|
System load too heavy.
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Check loopback connection.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error.
|
|
6016
|
Incomplete
read on Port name,
len number should be number,
speed = number
|
System load too heavy.
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Check loopback connection.
|
|
Bad serial port hardware
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error.
|
|
6018
|
name:
port not ready for writing after number seconds,
speed = number
|
System load too heavy
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Check loopback connection.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error.
|
|
6020
|
packet
data miscompare, cnt = number exp
= value, obs = value,
device = name, speed
= number
|
System load too heavy
|
Reduce the system load.
|
|
Loopback connection defective.
|
Check loopback connection.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error.
|
|
6021
|
name:
port not ready for reading after number seconds,
no data available, speed = number
|
System load too heavy.
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Check loopback connection.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error.
|
|
6022
|
name:
port not ready for writing after number seconds,
wrote number bytes
out of number. Baud rate
= number
|
System load too heavy.
|
Reduce the system load.
|
|
Loopback connection missing or defective.
|
Check loopback connection.
|
|
Bad serial port hardware.
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error
|
|
8001
|
Test Type a_to_b
is not allowed on Quick Test!
|
|
|
|
8002
|
name:
open() failed, error = error_message
|
|
|
|
8003
|
Invalid Data Type:
I=text
|
|
|
|
8004
|
name:
poll() error, (revents & (POLLERR | POLLHUP | POLLNVAL)) = value
|
|
|
|
8005
|
Siemens serial
device (se) does not support synchronous internal loopback test
|
|
|
|
8006
|
Invalid port parameter: name
|
|
|
|
8007
|
Invalid device
name 'name', must
specify either zsX or
seX, where X is the
first instance number of a device pair (ex., zs0)
|
|
|
|
8009
|
Failed ioctl name,
device = name, error
= error_message
|
|
|
|
8010
|
name:
Not able to push Tty compatibility STREAMS module
|
|
|
|
8011
|
Invalid Test Type:
T=name
|
|
|
|
8012
|
Invalid Mode: M=name
|
|
|
|
8013
|
name device
does not exist
|
|
|
|
8014
|
Invalid baud_rate: number
|
|
|
|
8015
|
write() to name failed: error_message,
baud rate = number
|
|
|
|
8016
|
read() to name failed: error_message,
baud rate = number
|
|
|
|
8017
|
Invalid size, requested
= number bytes, min
= number, max number
|
|
|
|
8018
|
Could
not open name after waiting number seconds
|
Another process is using the port
|
Stop other process using the port.
|
|
Port is hung
|
If the problem persists, contact your authorized Sun service provider.
|
|
Bad serial port hardware
|
|
System software error
|
|
8021
|
name:
No valid packets returned after number attempts,
last error = error_message,
wrote number packets,
read number packets,
device accounting shows number packets
sent and number packets
received
|
System load too heavy
|
Reduce the system load.
|
|
Timeout too short
|
Increase Sync_Poll_Count from pop menu.
|
|
Loopback connection missing or defective
|
Check the loopback connection.
|
|
Bad serial port hardware
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error
|
|
8022
|
printdlprim: unsupported primitive
type value
|
|
|
|
8023
|
stringtoaddr: invalid input
string: text
|
|
|
|
8025
|
dlinfoack: response ctl.len
too short: number
|
|
|
|
8026
|
dlinfoack: DL_INFO_ACK was
not M_PCPROTO
|
|
|
|
8027
|
dlokack: response
ctl.len too short: number
|
|
|
|
8028
|
dlokack: DL_OK_ACK
was not M_PCPROTO
|
|
|
|
8029
|
dlerrorack: response ctl.len
too short: number
|
|
|
|
8030
|
dlerrorack: DL_OK_ACK
was not M_PCPROTO
|
|
|
|
8031
|
dlbindack: response ctl.len
too short: number
|
|
|
|
8032
|
dlbindack: DL_OK_ACK
was not M_PCPROTO
|
|
|
|
8033
|
sigalrm: TIMEOUT
|
|
|
|
8037
|
invalid packet
length: number
|
|
|
|
8038
|
name:
poll() failed, error = error_message
|
System load too heavy
|
Reduce the system load.
|
|
Bad serial port hardware
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error
|
|
8039
|
Failed I_STR ioctl,
cmd = name, device
= name, error = error_message
|
|
|
|
8040
|
name:
No packets sent, last error = error_message, wrote number packets, read number packets, device
accounting shows number packets
sent and number packets
received
|
No transmit clock present
|
Reduce the system load.
|
|
System load too heavy
|
Increase Sync_Poll_Count from the pop menu.
|
|
Timeout too short
|
Check the loopback connection.
|
|
Loopback connection missing or defective
|
If the problem persists, contact your authorized Sun service provider.
|
|
Bad serial port hardware
|
|
System software error
|
|
8041
|
Sporadic
packets detected on name.
The port must be quiescent before running test
|
Another process is generating activity on the port
|
Stop other process using the port.
|
|
Bad serial port hardware
|
Stop other process using the port.
|
|
System software error
|
|
8042
|
syncinit: name missing minor
device number
|
|
|
|
8046
|
Test requires local
or remote modem loopback (external data loop, external clocking)
|
|
|
|
8047
|
name loopback
type not allowed on Connection test
|
|
|
|
8048
|
name loopback
type not allowed on online mode
|
|
|
|
8049
|
Invalid baud rate
for device name, select between number and number
|
|
|
|
8050
|
name internal
loopback test not allowed on name device
|
|
|
|
8051
|
Thread creation
failed, error_message
|
|
|
|
8054
|
name:
At least number packets
dropped (tolerance = number), last
error = error_message. Wrote number packets, read number packets. Device
statistics shows number packets
sent and number packets
received. number packets
dropped in outbound queueing, number packets
dropped in inbound queueing
|
System load too heavy
|
Reduce the system load.
|
|
Loopback connection missing or defective
|
Increase the drop tolerance option.
|
|
Bad serial port hardware
|
Check the loopback connection.
|
|
System software error
|
If the problem persists, contact your authorized Sun service provider.
|
|
8055
|
name: number bad
packets received, last error = error_message,
wrote number packets,
read number packets,
device accounting shows number packets
sent and number packets
received
|
System load too heavy
|
Reduce the system load.
|
|
Loopback connection missing or defective
|
Check the loopback connection.
|
|
Bad serial port hardware
|
If the problem persists, contact your authorized Sun service provider.
|
|
System software error
|