SunVTS 2.1.3 Test Reference Manual
  Cerca solo questo libro
Scarica il manuale in formato PDF
CHAPTER 32

Environmental Sensing Card Test (sentest)


sentest checks the SCSI Environmental Sensing card (SEN) installed in the SPARCstorage RSM to monitor the enclosure environment. The SEN card monitors the enclosure's over-temperature condition, fan-failures, power-supply failures, and drive activity.
sentest verifies the SEN card by first setting each control function to a predetermined value, and then reading it back to verify if the value is correct.
sentest verifies the following control functions in the enclosure:
  • Alarm (enable/disable)-sentest toggles the alarm to the disable state, then to the enable state.
  • Alarm time (0-0xff seconds)-sentest sets the time (from 0 to 4095), then reads it back to verify the time setting.
  • Drive fault LED (DL0-DL6)-sentest toggles each LED to its OFF and ON states.
sentest is a nonscalable test. It cannot verify the control function settings correctly if another instance is changing the setting.

sentest Options

Grafica

FIGURE 32-1 sentest

TABLE 32-1 sentest
sentest OptionDescription
Test TypeSpecifies the test to be performed. Norm test type performs normal testing as alarm enable/disable, alarm time setting, and drive LED on/off testing; Interactive test type reports the current enclosure status.
Enc_stateSpecifies which subsystem's status in the enclosure is reported. Default is ALL. This test is only used with the inter test type and in Functional test. The test options are: ·Alarm enable/disable status

·Drive present status

·Drive LED status

·Power modules status

·Fan modules status

·Over temperature, abs (abnormal, no immediate attention needed), chk (abnormal, immediate attention needed) status ·All of the above


sentest Test Modes

sentest supports all three test modes. Each mode performs a different test scheme on the SEN card.
TABLE 32-2 sentest
Test ModeDescription
Connection TestChecks the device connection by opening the device. If the device
does not open, the device is not connected.
Functional TestChecks three components within the enclosure. It checks alarm enable/disable, alarm time setting, and the drive LEDs. It does not test the power on/off function (only functions whose values can be changed are tested).
Online ModeProvides a means to run sentest through SyMON. In Online mode, the following Functional Test description applies: sentest opens the device and reports the current enclosure status.

sentest Command Line Syntax

/opt/SUNWvts/bin/sentest standard arguments
-o dev=interface,test=type,enc=component

TABLE 32-3 sentest
ArgumentExplanation
dev=interfaceSEN card device name; the default value is ses0.
test=typeSpecifies the test type; select Norm for normal testing or Inter for interactive testing; the default value is Norm. Possible values are: norm and inter.
enc=componentIndicates which part of the enclosure status is reported; the default value is ALL. Possible values are: enalm, dp, dl, pm, fan, ovt, and ALL.

sentest Error Messages

TABLE 32-4 sentest
Error MessageProbable Cause(s)Recommended Action
6000Check alenb failed, exp=value, obs=value

6001Check alenb failed, exp=value, obs=value

6002Check alenb failed, exp=value, obs=value

6003Check altime failed, exp time=value, obs=value

6004Fan failed

6005Dual fan failed

6006Enclosure over
temperature


6007Device failed, need immediate attention

TABLE 32-4 sentest(Continued)
Error MessageProbable Cause(s)Recommended Action
6008Power module A failed

6009power module B failed

8000power module B failed

8001ioctl get state failed, errmsg=message

8002ioctl get state failed, errmsg=message