- CHAPTER 11
StorEdge 1000 Enclosure Test (enctest)
-
enctest tests the StorEdge 1000 enclosures. The enclosure can support either 12 1" 4GB drives or 8 1.6" 9GB drives and have redundant power and cooling. Two enclosure models are available:
-
- StorEdge A1000 - Disk Tray with the hardware RAID controller
- StorEdge D1000 - Disk Tray without the hardware RAID controller.
-
enctest can be used for validation, configuration verification, repair verification, and fault isolation of both models.
- The enctest probe detects all the connected StorEdge enclosures and displays the status of the various elements in the enclosure.
-
enctest sets the StorEdge D1000 LEDs as follows:
-
TABLE 11-1 enctest
| LED State | Indicated Condition |
| On | Unrecoverable or critical condition |
| Blinking | Non-critical condition |
| Off | Informational or no condition to report |
-
Note - NOTE: The ses driver must be present on the system with the StorEdge enclosure(s). If the ses driver is not present, SunVTS will not detect the StorEdge hardware. Use the following command to see if the ses driver is present: pkginfo SUNWses
- Install the package if necessary.
-
enctest reports the status of the various elements in the enclosure. An error is registered if an unrecoverable or critical condition is detected. Non-critical conditions are reported through warning messages. TABLE 11-2 describes the information that is reported for each enclosure element.
-
TABLE 11-2 enctest
| Enclosure Element | Information reported (per device slot) |
| Disk | Present/Not Present
Failed/OK |
| Power supply | Present/Not Present
Failed/OK |
| Fan | Present/Not Present
Failed/OK |
| Temperature | OK/Over temperature |
| RPA cache Battery (StorEdge A1000 only) | OK/Low Charge |
enctest Options

FIGURE 11-1 enctest
-
TABLE 11-3 enctest
| enctest Options | Description |
| Display Enclosure Status | When enabled, the status of the enclosure elements are displayed as messages in the SunVTS console. These messages are also logged in the SunVTS info log file. |
| LED Test | When enabled, the LEDs associated with the disks are flashed for a short period of time. |
| Interval Between Passes | Sets the minimum delay between successive invocations of the test. |
enctest Test Modes
-
TABLE 11-4 enctest
| Test Mode | Description |
| Connectivity Mode | The enclosure status summary bits are read. Detailed information is reported only if an unrecoverable or critical condition is detected. |
| Functional Mode | When started through Symon, the LED test is not allowed and the "Display Enclosure Status" option is disabled by default. When started through the regular SunVTS GUI, all options are allowed. |
enctest Command Line Syntax
-
/opt/SUNWvts/bin/enctest standard_arguments -o dev=device_name, disp=enable|disable, led=enable|disable, delay=delay_in_seconds
-
TABLE 11-5 enctest
| Argument | Explanation |
| dev | This is the name of a ses device in the enclosure. |
| disp | Detailed status information regarding the enclosure elements will be displayed if enabled |
| led | Option to enable or disable the LED test. |
| delay | Minimum delay between successive invocations of the test. |
enctest Error Messages
-
TABLE 11-6 describes the enctest error messages, probable causes, and recommended actions.
-
TABLE 11-6 enctest
| Error Message | Probable Cause(s) | Recommended Action |
| 8000 Failed to open device. | System error. Cable loose or disconnected or device not configured.
| Verify the cable is properly connected and the device configured.Contact your authorized Sun service representative. |
| 8001 Failed to communicate with the enclosure | System error. Cable loose or disconnected or device not configured.
| Verify the cable is properly connected and the device configured.Contact your authorized Sun service representative. |
| 8002 Cannot proceed further due to lack of memory | Heavy system load. | Please try later. |
| 8003 unrecoverable|critical|non-critical informational condition detected in the enclosure |
|
|
-
TABLE 11-6 enctest(Continued)
| Error Message | Probable Cause(s) | Recommended Action |
| 8004 Failed to obtain list of enclosure elements | System error | Contact your authorized Sun service representative. |
| 8005 Failed to obtain status of an enclosure element | System error | Contact your authorized Sun service representative. |
| 8006 Failed to set the status of an enclosure element | System error | Contact your authorized Sun service representative. |
|
|