APPENDIX D

Default Solstice SyMON Rules


This appendix describes the default rules for this release of Solstice SyMON. Use this appendix to determine the rules that are incorporated into this Solstice SyMON release. By identifying the default rules, you can determine whether or not you need to write a new rule.

Note - The sample.tcl file in Solstice SyMON 1.1 through 1.3 contained only a comment.

TABLE D-1 describes the default rules supplied with this release of Solstice SyMON. The columns in the table describe the following:
  • Column 1 is the rule number.
  • Column 2 is a description of the rule.
  • Column 3 is the action taken when the condition is true.
TABLE D-1
Rule..Description
Number
Action
General: syrules.tcl
0....Symond statusalarm, snmp
1....Server statusalarm, snmp
3....Log Scanner statusalarm, snmp
4....Kernel Reader statusalarm, snmp
6....Delay initial Log Scanner and death statusnone
7....Delay initial Kernel Reader death status

8....Warning if label contains "."

none
9....Warning if label contains "*"alarm, snmp
General: egrules.tcl
TABLE D-1 (Continued)
Rule..Description
Number
Action
50....Trim event log if getting fullalarm, snmp
51....Warning when maximum number of events is nearalarm, snmp
52....Warning when ls_hist is corruptedalarm, snmp
53....Warning on incorrect Tcl rule syntaxalarm, snmp
General: swrules.tcl
100...Disk busyalarm, snmp
102...Swap spacealarm, snmp
103...CPU swapping and pagingalarm, snmp
104...CPU loadalarm, snmp
105...File system fullalarm, snmp
106...No swap spacealarm, snmp
General: hwrules.tcl
209...SIMM erroralarm, snmp
210...ssd hardware erroralarm, snmp
211...ssd fatal erroralarm, snmp
212...SIMM erroralarm, snmp
214...configd.*.status failingalarm, snmp
216...CPU panicalarm, snmp
217...Tape error rate highalarm, snmp
219...ssd off-linealarm, snmp
220...ssd okay (online)alarm, snmp
222...Fatal SunVTS erroralarm, snmp
223...SunVTS erroralarm, snmp
General: pfrules.tcl
300...SIMM errorsadd_pfa SIMM
301...Disk soft errorsadd_pfa DISK
302...Disk soft errors from smart drivesalarm, snmp
303...Check SIMM (test period 1)alarm, snmp
304...Check SIMM (test period 2)alarm, snmp
TABLE D-1 (Continued)
Rule..Description
Number
Action
305...Check SIMM (test period 3)alarm, snmp
306...Check disk pfa (warning)alarm, snmp
307...Check disk pfa (severe)alarm, snmp
308...Trims pfa historynone
General: cprules.tcl
400...CPU overload over x hoursalarm, snmp, add_cpa
401...Disk busy over x hoursalarm, snmp, add_cpa
402...Swap space low over x hoursalarm, snmp, add_cpa
403...Meta CPU events (check_cpa_cpu)alarm, snmp
404...Meta disk events (check_cpa_disk)alarm, snmp
405...Meta swap events (check_cpa_swap)

406...Trims cpa history

407...Initializes timestamp for rules 400 and 402

alarm, snmp
Platform-Specific Rules: SPARCserver 1000(E), SPARCcenter 2000(E ) -
SS1000.tcl, SC2000.tcl
1002...Config Reader statusalarm, snmp
1005...Delay initial Config Reader death statusnone
1207...system.*.*.*.statusalarm, snmp
1208...system.*.*.*.*.*.*.statusalarm, snmp
1224...system.*.*.*.*.*.*.*.statusalarm, snmp
1225...Corrected ECC erroralarm, snmp
Platform-Specific Rules: Ultra Enterprise 450: UE450.tcl
1002...Config Reader statusalarm, snmp
1005...Delay initial configd death statusnone
1204...system.*.fan.statusalarm, snmp
1205...system.*.*.*.temperaturealarm, snmp, mailto
1207...system.*.*.*.statusalarm, snmp
TABLE D-1 Default Solstice SyMON Rules (Continued)

 Rule        Description                             Action  
 Number  


1208 system.*.*.*.*.*.*.status alarm, snmp 1212 Power supply state alarm, snmp 1213 Power supply limit alarm, snmp 1214 Power supply current share alarm, snmp 1215 Power supply temperature alarm, snmp, mailto 1224 system.*.*.*.*.*.*.*.status alarm, snmp 1225 Corrected ECC error alarm, snmp
Platform-Specific Rules: Ultra Enterprise 3000, 4000, 5000, 6000: UEnterprise.tcl 1002 Config Reader status alarm, snmp 1005 Delay initial Config Reader death status none 1201 Hot plug charge DC status alarm, snmp 1202 Hot plug precharge DC status alarm, snmp 1203 system.*.status alarm, snmp 1204 Fan status alarm, snmp 1205 CPU board temperature alarm, snmp, mailto 1206 I/O and clock board temperature alarm, snmp, mailto 1207 system.*.*.*.status alarm, snmp 1208 system.*.*.*.*.*.status alarm, snmp 1209 system.*.*.*.*.*.*.status alarm, snmp 1213 Hot plug "removed" alarm, snmp 1215 Hot plug "hotplugged into" alarm, snmp 1218 system.*.*.*.*.status alarm, snmp 1220 Hot plug "installed" alarm, snmp 1221 Redundant power status alarm, snmp
Platform-Specific Rules: Ultra Enterprise 150: UEnterpriseI.tcl 1002 Config Reader status alarm, snmp
TABLE D-1 (Continued)
Rule NumberDescriptionAction
1005Delay initial configd death statusnone
1207system.*.*.*.statusalarm, snmp
1208system.*.*.*.*.*.*.statusalarm, snmp
1224system.*.*.*.*.*.*.*.*.*.statusalarm, snmp