- APPENDIX D
Default Solstice SyMON Rules
- This appendix describes the default rules for this release of Solstice SyMON. Use this appendix to determine the rules that are incorporated into this Solstice SyMON release. By identifying the default rules, you can determine whether or not you need to write a new rule.
-
Note - The sample.tcl file in Solstice SyMON 1.1 through 1.3 contained only a comment.
-
TABLE D-1 describes the default rules supplied with this release of Solstice SyMON. The columns in the table describe the following:
-
- Column 1 is the rule number.
- Column 2 is a description of the rule.
- Column 3 is the action taken when the condition is true.
-
TABLE D-1
Rule..Description
Number | Action |
| General: syrules.tcl |
|
| 0....Symond status | alarm, snmp |
| 1....Server status | alarm, snmp |
| 3....Log Scanner status | alarm, snmp |
| 4....Kernel Reader status | alarm, snmp |
| 6....Delay initial Log Scanner and death status | none |
| 7....Delay initial Kernel Reader death status 8....Warning if label contains "."
| none |
| 9....Warning if label contains "*" | alarm, snmp |
| General: egrules.tcl |
|
-
TABLE D-1 (Continued)
Rule..Description
Number | Action |
| 50....Trim event log if getting full | alarm, snmp |
| 51....Warning when maximum number of events is near | alarm, snmp |
| 52....Warning when ls_hist is corrupted | alarm, snmp |
| 53....Warning on incorrect Tcl rule syntax | alarm, snmp |
| General: swrules.tcl |
|
| 100...Disk busy | alarm, snmp |
| 102...Swap space | alarm, snmp |
| 103...CPU swapping and paging | alarm, snmp |
| 104...CPU load | alarm, snmp |
| 105...File system full | alarm, snmp |
| 106...No swap space | alarm, snmp |
| General: hwrules.tcl |
|
| 209...SIMM error | alarm, snmp |
| 210...ssd hardware error | alarm, snmp |
| 211...ssd fatal error | alarm, snmp |
| 212...SIMM error | alarm, snmp |
| 214...configd.*.status failing | alarm, snmp |
| 216...CPU panic | alarm, snmp |
| 217...Tape error rate high | alarm, snmp |
| 219...ssd off-line | alarm, snmp |
| 220...ssd okay (online) | alarm, snmp |
| 222...Fatal SunVTS error | alarm, snmp |
| 223...SunVTS error | alarm, snmp |
| General: pfrules.tcl |
|
| 300...SIMM errors | add_pfa SIMM |
| 301...Disk soft errors | add_pfa DISK |
| 302...Disk soft errors from smart drives | alarm, snmp |
| 303...Check SIMM (test period 1) | alarm, snmp |
| 304...Check SIMM (test period 2) | alarm, snmp |
-
TABLE D-1 (Continued)
Rule..Description
Number | Action |
| 305...Check SIMM (test period 3) | alarm, snmp |
| 306...Check disk pfa (warning) | alarm, snmp |
| 307...Check disk pfa (severe) | alarm, snmp |
| 308...Trims pfa history | none |
| General: cprules.tcl |
|
| 400...CPU overload over x hours | alarm, snmp, add_cpa |
| 401...Disk busy over x hours | alarm, snmp, add_cpa |
| 402...Swap space low over x hours | alarm, snmp, add_cpa |
| 403...Meta CPU events (check_cpa_cpu) | alarm, snmp |
| 404...Meta disk events (check_cpa_disk) | alarm, snmp |
| 405...Meta swap events (check_cpa_swap) 406...Trims cpa history 407...Initializes timestamp for rules 400 and 402
| alarm, snmp |
Platform-Specific Rules: SPARCserver 1000(E), SPARCcenter 2000(E ) -
SS1000.tcl, SC2000.tcl |
| 1002...Config Reader status | alarm, snmp |
| 1005...Delay initial Config Reader death status | none |
| 1207...system.*.*.*.status | alarm, snmp |
| 1208...system.*.*.*.*.*.*.status | alarm, snmp |
| 1224...system.*.*.*.*.*.*.*.status | alarm, snmp |
| 1225...Corrected ECC error | alarm, snmp |
| Platform-Specific Rules: Ultra Enterprise 450: UE450.tcl |
|
| 1002...Config Reader status | alarm, snmp |
| 1005...Delay initial configd death status | none |
| 1204...system.*.fan.status | alarm, snmp |
| 1205...system.*.*.*.temperature | alarm, snmp, mailto |
| 1207...system.*.*.*.status | alarm, snmp |
-
TABLE D-1 Default Solstice SyMON Rules (Continued)
-
Rule Description Action
Number
1208 system.*.*.*.*.*.*.status alarm, snmp
1212 Power supply state alarm, snmp
1213 Power supply limit alarm, snmp
1214 Power supply current share alarm, snmp
1215 Power supply temperature alarm, snmp,
mailto
1224 system.*.*.*.*.*.*.*.status alarm, snmp
1225 Corrected ECC error alarm, snmp
Platform-Specific Rules: Ultra Enterprise 3000, 4000, 5000, 6000:
UEnterprise.tcl
1002 Config Reader status alarm, snmp
1005 Delay initial Config Reader death status none
1201 Hot plug charge DC status alarm, snmp
1202 Hot plug precharge DC status alarm, snmp
1203 system.*.status alarm, snmp
1204 Fan status alarm, snmp
1205 CPU board temperature alarm, snmp,
mailto
1206 I/O and clock board temperature alarm, snmp,
mailto
1207 system.*.*.*.status alarm, snmp
1208 system.*.*.*.*.*.status alarm, snmp
1209 system.*.*.*.*.*.*.status alarm, snmp
1213 Hot plug "removed" alarm, snmp
1215 Hot plug "hotplugged into" alarm, snmp
1218 system.*.*.*.*.status alarm, snmp
1220 Hot plug "installed" alarm, snmp
1221 Redundant power status alarm, snmp
Platform-Specific Rules: Ultra Enterprise 150: UEnterpriseI.tcl
1002 Config Reader status alarm, snmp
|
-
TABLE D-1 (Continued)
| Rule Number | Description | Action |
| 1005 | Delay initial configd death status | none |
| 1207 | system.*.*.*.status | alarm, snmp |
| 1208 | system.*.*.*.*.*.*.status | alarm, snmp |
| 1224 | system.*.*.*.*.*.*.*.*.*.status | alarm, snmp |
|