APPENDIX B

Config Reader


The Config Reader determines the configuration of a machine, along with the status of its components. Its output is depicted in these consoles:
  • Physical View
  • Logical View
Tables B-2 through B-4 list the Config Reader data hierarchy. Use the information in this appendix if you want to write event rules that monitor the output of the Config Reader.

Terminology

The terms in TABLE B-1 are used to explain the information in TABLE B-2.
TABLE B-1
PropertyTermDefinition
PinstanceThis is a decimal or hexadecimal number acquired by reading /etc/path_to_inst, which maps physical device names to the instance number; refer to the man page for more information.
TABLE B-1
PropertyTermDefinition
Pupa-portidThis property exists for SBus and CPU units. Each board has two CPU slots, A and B, which have unique numbers. For example, board 0 has upa-portid 0 and 1, and board 1 has upa-portid 2 and 3, and so on. portid/2 = slot number.
Pupa-midThis property is displayed for fhc, sbus, cpu-unit and central modes. It is always equal to upa-portid.
PhpuThis stands for hot plugable unit. You can replace hot plugable units without powering the system down.

Data Hierarchy

These abbreviations are used in the following tables in this chapter:
  • I = Integer
  • H = Hexadecimal
  • A = ASCII
Table B-2 lists the Config Reader data hierarchy for the Ultra Enterprise 3000, 4000, 5000, and 6000 systems that describe the configuration of the host. They can also be electrical entities. For example, the system_3v node is not a physical entity but is the input voltage to system boards.
Each node has a set of properties that describes its state; for example, if an LED is on or off, or if a voltage level is acceptable. The node and its properties are grouped together in TABLE B-2 in the following order:
  • The first column contains the node or property name.
  • The second column specifies whether the parameter is a node (N) or a property (P). A node in the hierarchy is a starting point for a branch of the hierarchy. All properties that belong to a node appear below the node and are marked with a P. For example, cpu.busy and cpu.user fall under the cpu node. The node and its properties are grouped together.
  • The third column contains the data type of the property. Note that the Config Reader always encloses the value of a property between double quotes (" ").
  • The fourth column lists the default value, which is not listed for every entry.
  • The last column explains the meaning of the node or property.

Ultra Enterprise 3000, 4000, 5000, and 6000

The following table is the Config Reader data hierarchy for the Ultra Enterprise 3000, 4000, 5000, and 6000 server systems.
TABLE B-2
Node or Property and NameNode or PropertyTypeDefault ValueDescription
AC_PSN


statusP"A""OK"/"FAIL"AC connector and switch
SUNW,fasN

Host Bus Adapter driver
tape_countP"I"Number of tapes attached to a particular slot
disk_countP "I"Number of disks attached to a particular slot
instance*P "I"
device_type*P "A""scsi"
SUNW,ffb(N)N

UPA color frame buffer and graphics accelerator (N) = instance number
bufferP"A""Single"/
"Double"
3DRAMP"A"3-D RAM model and version number
DACP"A"Revision of DAC chip
FBC_versionP"H "
revisionP"A"Revision of FFB board
instance*P"I"
upa-portid*P"I"
widthP"I"Pixels
heightP"I"Pixels
device_typeP"A""display"
modelP"A"
SUNW,hmeN

Fast Ethernet device driver
* Refer to Table B-1.



TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
instance*P"I"

device_typeP"A""network"
SUNW,leoN

Double-buffered SBus color frame buffer and graphics accelerator
instance*P"I"
widthP"I"Pixels
heightP"I"Pixels
modelP"A"
device_typeP"A""display"
SUNW,pln(N)N

SPARCstorage Array
disk_countP"I"Number of attached disks
device_typeP"A"SPARCstorage Array
instance*P"I"
SUNW,rtvcN

Real-time video capture
instance*P "I"
modelP
SUNW,soc(N)*N

Serial Optical Controller device driver; (N) = instance number
device_typeP"A"See DescriptionSerial Optical Channel Processor Host Adapter
instance*P"I"
modelP
soc-wwnP"I"World Wide Web device name
port-wwnsP"I"
board(N)N

(N) = board number
hpuP"A""yes"Hot plug unit
temperatureP"A""N C< " where N is an integer
* Refer to Table B-1.



TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
state=P"A"
. "active:" Normal state for boards after the operating system has booted . "disabled:" Disabled by the PROM because it was listed in the 'disabled-board-list' property in the options node . "failed:" A board that is failed by POST and powered off in the testing phase of PROM operations . "hot-plug:" Intermediate state after a board is hotplugged

. "low-power:" The state that hotplug boards are in before they are removed . "unknown:" Unused

fruP"A""yes"Field replaceable unit
typeP"A"See DescriptionOne of: clock, cpu/memory, Dual SBus I/O, disk-board, SBus/FFB I/O, pci I/O
board-numP"I"For example, Ultra-Enterprise 3000: up to 4
memory_sizeP "A""N MB," N is an integer (CPU/memory boards only)
cdromN


mounted_partitionsP"I"
device_typeP"A""CD-ROM"
nameP"A"For example c0t6d0
instance*P"I"
centralN

Only exists under the clock board
instance*P"I"
upa-mid*P"I"
clock-boardN


* Refer to Table B-1.



TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
instance*P"I"

cpu-unit(N)N

(N) = unit
fruP"A""yes"Field replaceable unit
clock-frequencyP"A"N MHz, where N is an integer
cpu-typeP"A"For example sparc
statusP"A""online"/
"offline"
modelP"A"
processor-idP"I"2*board number (+1 if cpu-unit=B )
unitP"A""A" or "B" (each board takes two CPUs)
upa-mid*P"I"
upa-portid*P"I"
icache-size*P"A""N KB" or "N MB," where N is a fixed point number
dcache-sizeP"A""N KB" or "N MB," where N is a fixed point number
ecache-sizeP"A""N KB" or "N MB," where N is a fixed point number
device_typeP"A""cpu"
board#P"A"Board number on which this node resides
disk_fanN

Exists only in Ultra Enterprise 3000 systems
hpuP "A""yes"Hotplug unit?
statusP "A""OK"/"FAIL"
fanN

In the Ultra Enterprise 4000, 5000, and 6000, the AC_PS has a fan node
statusP "A""OK"/"FAIL"
* Refer to Table B-1.



TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
fhcN

Fire Hose controller; one associated with each AC; contains board CSR, which controls on-board devices such as PROMs, RAM and UARTs
instance*P "I"
upa-mid*P "I"
version#P "I"
Version number
board#P "I"
Board number on which this node resides
modelP "A"
Address controller
acN


instance*P "I"
version#P "I"
modelP "A"
device_typeP "A""memory-controller"
eepromN

Electrically programmable read-only memory
modelP"A"
environmentN
instance*P"I"
flashpromN


instance*P"I"
modelP"A"
sbus-speedP


keyswitch



positionP"A""Normal Mode," "Secure mode," or "Diagnostic mode"
* Refer to Table B-1.



TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
led(N)N

Power supplies have two LEDs: green (off = no power) and amber (on=FAIL); boards have three LEDs; refer to the Ultra Enterprise Maintenance Manual for LED combinations
led-numP"I"
1, 2, or 3
stateP"A""on"/"off"
peripheral_PS(N)N

184w power supply for SCSI peripherals, additional power for boards in system and pre-charge power for hot plugging boards
hpuP"A" "yes"Hot plug unit
statusP"A""OK"/"FAIL"
unit#P "I"Unique number of this power supply
fruP"A" "yes"Field replaceable unit
nf(N)N

SBus FDDI Driver
etherP"A"Ethernet address; for example 8:0:20:75:af:f8
inetP "I"Internet address; for example 129.146.65.45
symbolP"A"Network name corresponding
to the inet address above
nameP"A"Driver name; for example, nf0
instance*P"I"
modelP"A"
device_typeP"A""network"
power_supply(N)N

300w board supply, (N) = unit number
hpuP"A""yes"Hot plug unit
statusP"A""OK"/"FAIL"
* Refer to Table B-1.



TABLE B-2 (Continued)
Node or
Node or Property and Name...Property Type Default Value

Description
unit#..........PUnique number of the power supply
fru............P..."A" "yes"Field replaceable unit
sbus(N).........N

instance*........P..."I"
upa-portid*.......P..."I"
upa-mid*.........P..."I"
version#*........P
Peripheral bus; N=instance
number
board#..........P..."A"

device_type*.......P..."A" "sbus"

model..........P

Board number on which this node resides
network_count......P..."I"Network devices attached to this SBus
remote_console.....N

status=.........P..."A" "Enabled/ Disabled"


sd(0)..........N
fru............P..."A" "yes"

mounted_partitions...P..."I"

device_type.......P..."A"

Field replaceable unit
name...........P..."A"

instance.........P..."I"
"disk" for example,
"c0t0d0"
The following data, which is a continuation of the properties that go with the sd(0) node (above), is the output of Config Reader if the disk has mounted partition.
name...........P..."A"For example, c0t0d0s0
percent_used.......P..."I"For example, 49%
total_bytes.......P..."I"n MBytes or n KBytes
avail_bytes.......P..."I"n MBytes or n KBytes
* Refer to Table B-1.
TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
used_bytesP"I"
n MBytes or n KBytes
device_type*P"A"
partition
export nameP"A"
For example, c0t0d0s7
simm(0)N


board_reference_numberP"A"
slotP "I"
CPU/memory slot where this SIMM resides
sizeP"A"
typeP"A"
dram
fruP"A""yes"Field replaceable unit
sramN

Static RAM
instance*P"I"
st(N)N

SCSI tape, N is the instance number
fruP"A""yes"Field replaceable unit
modelP"A"For example, Exabyte EXB- 8500 8mm
nameP"A"For example, /dev/rmt/0n
statusP"A""OK/FAIL"
device_typeP"A""tape drive"
instance*P "I"
systemN

Contains general properties of the system
total_processorsP"I"Number of processors in the machine
total_memoryP "A"N MB, where N is an integer
total_disksP "I"
total_tape_devicesP "I"
sample numberP "I"Since daemon started on server
* Refer to Table B-1.



TABLE B-2 (Continued)
Node or
Node or Property and Name...Property Type

Default Value

Description
timestamp........P... "A"
For example, Tue Mar 26 10:33:08 1996
hostname.........P... "A"
Machine name
OS............P..."A"
Value as returned by uname(2) in release field
OS_version........P..."A"
Value as returned by uname(2) in release field
architecture.......P..."A"
For example, sparc, mc68030, m32100, or 8386
machine.........P..."A"
For example, sun4u
platform.........P..."A"

serial_number......P..."I"


Value as returned by the uname -i command
System_clock_frequency P..."A"
N MHz, where N is an integer
The following nodes are not physical entities. They are the output of different power supplies in the system that is used for purposes such as hotplugging, and peripherals.

hot_plug_charges....N

fru............P..."A" "no"Field replaceable unit
auxiliary_5v.......N

status..........P..."A""OK"/"FAIL"
fru............P..."A""no"Field replaceable unit
peripheral_12v

status..........P..."A""OK"/"FAIL"
fru............P..."A""no"Field replaceable unit
peripheral_12v_precharge N

status..........P..."A""OK"/"FAIL"
fru............P..."A""no"Field replaceable unit
peripheral_5v......N

status..........P..."A""OK"/"FAIL"
fru............P..."A""no"Field replaceable unit
* Refer to Table B-1.

TABLE B-2 (Continued)
Node or Property and NameNode or PropertyTypeDefault ValueDescription
peripheral_5vprechargeN


statusP"A""OK"/"FAIL"
fruP"A""no"Field replaceable unit
system_5vN


statusP"A""OK"/"FAIL"
fruP"A""no"Field replaceable unit
system_5v_ prechargeN


statusP"A""OK"/"FAIL"
fruP"A""no"Field replaceable unit
system_3vN


statusP"A""OK"/"FAIL"
fruP"A""no"Field replaceable unit
system_3v_ prechargeN


statusP"A""OK"/"FAIL"
fruP"A""no"Field replaceable unit
* Refer to Table B-1.



SPARCserver 1000/1000E and SPARCcenter 2000/2000E

The following table is the Config Reader data hierarchy for the SPARCstation 1000/ 1000E and the SPARCcenter 2000/2000E.
TABLE B-3
NameNode or PropertyTypeDefault ValueDescription
QLGC, isp(N)N

(N) = unit number
device_typeP"A""SCSI

controller"

disk_countP"I"
fruP"A""yes"Field replaceable unit
instance*P"I"
modelP"A"
tape_countP"I"
board(N)N

(N) = board number; this is a unique number ranging from 0 to the maximum number of boards per machine
board-numP"I"same as N, above
fruP"A""yes"Field replaceable unit
stateP"A"One of "Active," "disabled," or "failed.". "active:" Normal state for boards after the operating system has booted

. "disabled:" Disabled by the PROM because it was listed in the 'disabled-board-list' property in the options node . "failed:" A board that is failed by POST and powered off in the testing phase of PROM operations

typeP"A""cpu/memory/io"
cgsix(N)N

(N) = unit number
device_typeP"A""display"
* Refer to Table B-1.



TABLE B-3 (Continued)
NameNode or PropertyTypeDefault ValueDescription
instance*P"I"

modelP"A"

cpu-unit(N)N

(N) = unit number
board#P"I"
Board number on which this node resides
clock-frequencyP"A""N MHz"
cpu-typeP"sparc"
device_typeP"cpu"
fruP"A""yes"Field replaceable unit
moduleP"A"
processor-idP"I"2*board number ( +1 if cpu-unit is "B")
sparc-versionP"I"
statusP"A""online"/
"offline"
unitP"A""A" or "B" (each board takes two CPUs)
dma(N)N

(N) = unit number
instance*P"I"
modelP"A"
esp(N)N

(N) = unit number
chipP"A"
device_typeP"A""SCSI

controller"

disk_countP"I"Number of disks attached to this node
instance*P"I"
tape_countP"I"Number of tapes attached to this node
io-unit(N)N


* Refer to Table B-1.



TABLE B-3 (Continued)
NameNode or PropertyTypeDefault ValueDescription
board#P"I"
Board number on which this node resides
device-idP"I"
instance*P"I"
mem-unit board#N"I"
Board number on which this node resides
device-idP"I"
device_typeP"A""memory"
sizeP"A""N MB"
statusP"A""OK"/"FAIL"
le(N)N

(N) = unit number
aliasP"le"
device_typeP"network"
etherP"8:0:20:74:30:43 "
inetP"129.146.235.47"
instance*P"I"
nameP"le0"
symbolP"pump"
lebuffer(N)N

(N) = unit number
instance*P"I"
modelP"A"
network_countP"I"
sbi(N)N

(N) = unit number
device_typeP"SBus card"
instance*P"I"
simm(N)N

(N) = unit number
group#P"I"
memory-typeP"RAM"
* Refer to Table B-1.



TABLE B-3 (Continued)
NameNode or PropertyTypeDefault ValueDescription
sizeP
"32MB"
sd(N)N

(N) = disk number
device_typeP
"disk"
fruP"A""yes"Field replaceable unit
instance*P"I"
mounted_partitionsP"I"
name="c1t3d0"P"A""N mbytes"Partition name
directory_nameP"A"For example, / or /usr
avail_bytesP"A""N mbytes"
device_typeP"partition"You don't see these partitions unless mounted_partitions != 0
nameP"c1t3d0s0"You don't see these partitions unless mounted_partitions != 0
percent_usedP"A""N%"You don't see these partitions unless mounted_partitions != 0
total_bytesP"A""N mbytes"You don't see these partitions unless mounted_partitions != 0
used_bytesP"A""N mbytes"You don't see these partitions unless mounted_partitions != 0
slot(N)N

Slot where boards are physically
installed; (N) = unit number
slot-numP"I"
sdN

This node only exists in cases where no disks are attached to the SCSI controller
device_typeP"A""block"
fruP"A""yes"Field replaceable unit
* Refer to Table B-1.



TABLE B-3 (Continued)
NameNode or PropertyTypeDefault ValueDescription
stN

This node only exists in cases where no tapes are attached
device_typeP"A""byte"
fruP"A""yes"Field replaceable unit
systemN


OSP"A"Value as returned by uname(2) in the release field
OS_versionP"A"Value as returned by uname(2) in the release field
System_clock_frequencyP"A""N MHz"
architectureP"A"For example, sparc, mc68030, m32100, or 8386
hostnameP"A"Machine name
machineP"A""sun4d"
platformP"A"Value as returned by the uname -i command
serial_numberP"I"
timestampP"A"
total_disksP"I"Number of disks attached to the machine
total_memoryP"A""N MB"
total_processorsP"I"Number of processors in the machine
total_tape_devicesP"I"Number of tapes attached to the machine
* Refer to Table B-1.



Ultra Enterprise 2 and150 System

The following table is the Config Reader data hierarchy for the Ultra Enterprise 2 and Ultra Enterprise 150 systems.
TABLE B-4
NameNode or PropertyTypeDefault ValueDescription
SUNW,fasN

Host Bus Adapter driver
tape_countP"I"
Number of tapes attached to a slot
disk_countP "I"
Number of disks attached to a slot
instance*P "I"
device_type*P "A""scsi"
SUNW,ffb(N)


UPA color frame buffer and graphics accelerator (N) = instance number
bufferP"A""Single"/
"Double"
3DRAMP"A"3-D RAM model and version number
DACP"A"Revision of DAC chip
FBC_versionP"H "
revisionP"A"Revision of FFB board
instance*P"I"
upa-portid*P"I"
widthP"I"Pixels
heightP"I"Pixels
device_typeP"A""display"
modelP"A"
SUNW,hmeN

Fast Ethernet device driver
instance*P"I"
device_typeP"A""network"
* Refer to Table B-1.



TABLE B-4 (Continued)
NameNode or PropertyTypeDefault ValueDescription
SUNW,leoN

Double-buffered SBus color frame buffer and graphics accelerator
instance*P"I"
widthP"I"
Pixels
heightP"I"
Pixels
modelP"A"
device_typeP"A""display"
SUNW,pln(N)N

SPARCstorage Array
disk_countP"I"Number of attached disks
device_typeP"A"SPARCstorage Array
instance*P"I"
SUNW,rtvcN

Real-time video capture
instance*P "I"
modelP
SUNW,soc(N)*N

Serial Optical Controller device driver; (N) = instance number
device_typeP"A"See DescriptionSerial Optical Channel Processor Host Adapter
instance*P"I"
modelP
soc-wwnP"I"World Wide Web device name
port-wwnsP"I"
system-boardN


state=P"A""active:" Normal state for boards after the operating system has booted "unknown:" Unused
fruP"A""yes"Field replaceable unit
board-numP"I"Always 1
memory_sizeP "A"N MB, where N is an integer (CPU/memory boards only)
cdromN


* Refer to Table B-1.



TABLE B-4 (Continued)
NameNode or PropertyTypeDefault ValueDescription
mounted_partitionsP"I"

device_typeP"A"
CD-ROM
nameP"A"
For example, c0t6d0
instance*P"I"
cpu-unit(N)N

(N) = unit
fruP"A""yes"Field replaceable unit
clock-frequencyP"A"N MHz, where N is an integer
cpu-typeP"A"For example, sparc
statusP"A""online"/
"offline"
modelP"A"
processor-idP"I"0 or 1 (only 0 possible on the Ultra Enterprise 150 system)
unitP"A""A" or "B" (only on UE-2)
upa-mid*P"I"
upa-portid*P"I"
icache-size*P"A"N KB or N MB, where N is a fixed point number
dcache-sizeP"A"N KB or N MB, where N is a fixed point number
ecache-sizeP"A"N KB or N MB, where N is a fixed point number
device_typeP"A""cpu"
nf(N)NSBus FDDI Driver
etherP"A"Ethernet address; for example, 8:0:20:75:af:f8
inetP "I"Internet address; for example, 129.146.65.45
symbolP"A"Network name corresponding to the inet address above
nameP"A"Driver name; for example. nf0
instance*P"I"
* Refer to Table B-1.



TABLE B-4 (Continued)
Node or

Name..........Property Type Default Value

Description
model.........P..."A"
device_type......P..."A" "network"

sbus(N)........N

instance*.......P..."I"
upa-portid*......P..."I"
upa-mid*........P..."I"
version#*.......P
device_type*.....P..."A" "sbus"
model.........P
Peripheral bus; N=instance
number
network_count.....P..."I"Network devices attached to this SBus
sd(0).........N
fru..........P..."A" "yes"

mounted_partitions..P..."I"

device_type......P..."A"

Field replaceable unit
name..........P..."A"
instance........P..."I"
"disk" for example, c0t0d0
The following data, which is a continuation of the properties that go with the sd(0) node (above), is the output of Config Reader if the disk has mounted partition.
name..........P..."A"For example, c0t0d0s0
percent_used.....P..."I"For example, 49%
total_bytes......P..."I"n MBytes or n KBytes
avail_bytes......P..."I"n MBytes or n KBytes
used_bytes......P..."I""n MBytes or n KBytes
device_type*.....P..."A""partition"
export name......P..."A"For example, c0t0d0s7
simm(N)........NN is simm instance.
slot..........P... "I"CPU/memory slot where this SIMM resides
* Refer to Table B-1.
TABLE B-4 (Continued)
NameNode or PropertyTypeDefault ValueDescription
sizeP"A"

typeP"A"
"dram"
fruP"A""yes"Field replaceable unit
board-reference-numberP"A'
Address of SIMM on board
st(N)NSCSI tape, N is the instance number
fruP"A""yes"Field replaceable unit
modelP"A"For example, Exabyte EXB-8500 8mm
nameP"A"For example, /dev/rmt/0n
statusP"A""OK/FAIL"
device_typeP"A""tape drive"
instance*P "I"
systemN

Contains general properties of the system
total_processorsP"I"Number of processors in the machine
total_memoryP "A"N MB, where N is an integer
total_disksP "I"
total_tape_devicesP "I"
sample numberP "I"Since daemon started on server
timestampP "A"For example, Tue Mar 26 10:33:08 1996
hostnameP "A"Machine name
OSP"A"Value as returned by uname(2) in release field
OS_versionP"A"Value as returned by uname(2) in release field
architectureP"A"For example, sparc, mc68030, m32100, or 8386
machineP"A"For example, sun4u
* Refer to Table B-1.



TABLE B-4 (Continued)
NameNode or PropertyTypeDefault ValueDescription
platformP"A"
Specific model of the hardware platform
serial_numberP"I"
System_clock_frequencyP"A"
N MHz, where N is an integer
sbus-board(N)N
The SBus board in slot N
board-numP"I"
The number of the board in its particular sbus
fruP"A""yes"Field replaceable unit
modelP"A"Board model--either a model name (if the board is identified by Solstice Symon) or the Open Boot PROM model string (for example, SUNW,501-2739)
stateP"A""active:" Normal state for boards after the operating system has booted
leN

Ethernet device driver
instance*P"I"
device_typeP"A""network"
etherP"A"Ethernet address; for example, "8:0:20:75:af:f8"
inetP "I"Internet address; for example, "129.146.65.45"
nameP"A"Driver name; for example, le0
device_typeP"A""network"
SUNW,fdtwoN

Floppy disk device
instance*P"I"
device_typeP"A""block"
fruP"A""yes"Field replaceable unit
* Refer to Table B-1.



If any component of a hierarchy path contains a period ( . ) in it, you may not be able to use the findlist function to find it. For example, if you search for the mount point /export/a0.test reported by the Config Reader via the path:
system.slot.board.io-unit.sbi.dma.esp.sd./export/a0.test
the node will not be found.  Instead, use:
system.slot.board.io-unit.sbi.dma.esp.sd.* to find this node.

Ultra Enterprise 450 System

TABLE B-5 lists the Config Reader data hierarchy for the Ultra Enterprise 450 system.
TABLE B-5
NameNode or PropertyTypeDefault ValueDescription
glmN

Host Bus Adapter driver
chassis-disk-groupP"I"
Shows which of the 5 in-chassis disk groups is attached to this controller; this property is not present if the controller is not attached to internal disks
clock-frequencyP"I"
Clock frequency of the controller (MHz)
logical-disk-
controller
P"A"
The logical controller name used
to refer to this controller in the
/dev/dsk directory
compatiblenP"A"
Alternate name for this node; may determine driver being used; will have value glm for SUN fast-wide SCSI controller
tape_countP"I"
Number of tapes attached to a slot
disk_countP "I"
Number of disks attached to a slot
instance*P "I"
modelP"A"Symbios,53C875Model name
device_type*P "A""scsi-2"
* Refer to Table B-1.



TABLE B-5 (Continued)
NameNode or PropertyTypeDefault ValueDescription
SUNW,ffb(N)N

UPA color frame buffer and graphics accelerator; N = instance number
bufferP"A""Single"/
"Double"
3DRAMP"A"3-D RAM model and version number
DACP"A"Revision of DAC chip
FBC_versionP"H "
revisionP"A"Revision of FFB board
instance*P"I"
upa-portid*P"I"
widthP"I"Pixels
heightP"I"Pixels
device_typeP"A""display"
modelP"A"
hmeN

Network device
compatiblenP"A"Alternate device name; will have value SUNW,hme for Sun Fast Ethernet device
instance*P"I"
device_typeP"A""network"
pln(N)N

SPARCstorage Array
disk_countP"I"Number of attached disks
device_typeP"A"SPARCstorage Array
instance*P"I"
soc(N)*N

Serial Optical Controller device driver; N = instance number
device_typeP"A"See DescriptionSerial Optical Channel Processor Host Adapter
instance*P"I"
modelP
* Refer to Table B-1.



TABLE B-5 (Continued)
NameNode or PropertyTypeDefault ValueDescription
soc-wwnP"I"
World Wide Web device name
port-wwnsP"I"
system-boardN


state=P"A"
"active:" Normal state for boards after the operating system has booted"unknown:" Unused
fruP"A""yes"Field replaceable unit
board-numP"I"Always 1
cdromNN


mounted_partitionsP"I"
device_typeP"A"CD-ROM
nameP"A"For example, c0t6d0
instance*P"I"
cpu-unit(N)N

N = unit; Possible values are 1 through 4
fruP"A""yes"Field replaceable unit
clock-frequencyP"A"N MHz, where N is an integer
cpu-typeP"A"For example, sparc
statusP"A""online"/
"offline"
modelP"A"
processor-idP"I"0 through 3
unitP"A""A1" or "B1"or "A2" or "B2"
upa-mid*P"I"
upa-portid*P"I"
icache-size*P"A"N KB or N MB, where N is a fixed point number
dcache-sizeP"A"N KB or N MB, where N is a fixed point number
ecache-sizeP"A"N KB or N MB, where N is a fixed point number
* Refer to Table B-1.



TABLE B-5 Ultra Enterprise 450 Config Reader Data Hierarchy (Continued)

                            Node or NamePropertyTypeDefault Value Description  


device_type P "A" "cpu" temperature P "A" N C< where N is an integer
pci(N) N Peripheral bus; N = instance number instance* P "I" clock-frequency P "I" Speed of the PCI bus in MHz (33 MHz or 66 MHz) upa-portid* P "I" upa-mid* P "I" version#* P device_type* P "A" "sbus" model P network_count P "I" Network devices attached to this SBus
sdN N SCSI disk; N is the instance number fru P "A" "yes" Field replaceable unit mounted_partitions P "I" device_type P "A" name P "A" "disk"; for example, c0t0d0 instance P "I" The following data, which is a continuation of the properties that go with the sdN node above, is the output of the Config Reader if the disk is physically located in the Ultra Enterprise 450 chassis. error_led P "A" On/Off State of the error LED of the disk disk-slot P "I" Slot number in the chassis front: 9 to 19 The following data, which is a continuation of the properties that go with the sdN node (above), is the output of Config Reader if the disk has mounted partition. name P "A" For example, c0t0d0s0 percent_used P "I" For example, 49% total_bytes P "I" n MBytes or n KBytes
* Refer to Table B-1.
TABLE B-5 (Continued)
NameNode or PropertyTypeDefault ValueDescription
avail_bytesP"I"
n MBytes or n KBytes
used_bytesP"I"
n MBytes or n KBytes
device_type*P"A"
Partition
export nameP"A"
For example, c0t0d0s7
mc(N)N

Memory controller; instance N
device_typeP"A"memory-bankDevice type
bank(N)N

Bank; instance N
device_typeP"A"memory-bankDevice type
bank-sizeP"A"N MbBank size in Mb
statusP"A""ok"Status of the bank--"missing
DIMMs," "mis-sized," or "ok"
interleave-groupP"I"Group of interleaved banks; only present if this bank is interleaved
dimm(N)N

N is dimm instance within the bank
slotP "I"Memory slot where this DIMM resides
statusP"A""ok"Status of DIMM--"unused,"
"partially used, " or "ok"
module-sizeP"A"
typeP"A""dram"
socket-nameP"A'Address of DIMM on board
fruP"A""yes"Field replaceable unit
st(N)N

SCSI tape, N is the instance number
fruP"A""yes"Field replaceable unit
modelP"A"For example, Exabyte EXB-8500 8mm
nameP"A"For example, /dev/rmt/0n
statusP"A""OK/FAIL"
device_typeP"A""tape drive"
* Refer to Table B-1.



TABLE B-5 (Continued)
NameNode or PropertyTypeDefault ValueDescription
instance*P "I"

systemN

Contains general properties of the system
total_processorsP"I"
Number of processors in the machine
ambient-temperatureP"A"nn CAmbient temperature of the system in degrees C
total_memoryP "A"N MB, where N is an integer
total_disksP "I"
total_tape_devicesP "I"
sample numberP "I"Since daemon started on server
timestampP "A"For example, Tue Mar 26 10:33:08 1996
hostnameP "A"Machine name
OSP"A"Value as returned by uname(2) in the release field
OS_versionP"A"Value as returned by uname(2) in the release field
architectureP"A"For example, sparc, mc68030, m32100, or 8386
machineP"A"For example, sun4u
platformP"A"Specific model of the hardware platform
serial_numberP"I"
System_clock_frequencyP"A"N MHz, where N is an integer
pci-board(N)N

The PCI board in slot N of the particular PCI bus
board-numP"I"The number of the board in its particular SBus
fruP"A""yes"Field replaceable unit
* Refer to Table B-1.



TABLE B-5 (Continued)
NameNode or PropertyTypeDefault ValueDescription
modelP"A"
Board model -- either a model name (if the board is identified by Solstice Symon) or the Open Boot PROM model string (for example, SUNW,501-2739)
stateP"A"
"active:" Normal state for boards after the operating system has booted
fdthreeN

Floppy disk device
instance*P"I"
fruP"A""yes"Field replaceable unit
device_typeP"A""block"
cpu-fansN

Rack of 3 fans cooling the processors and peripheral boards
statusP"A""OK"Status of fan group; "OK" if all fans OK
power-supply-fansN

Rack of 3 fans cooling the power supplies
statusP"A""OK"Status of fan group; "OK" if all fans OK
fan(N)N

Individual fan node
statusP"A""OK"Fan status
front-panel-keyswitchN


positionP"A"Position of key
power-supply(N)N

Power-supply node
current-shareP"A"State of current--sharing
limitP"A"State of current---limiting
statusP"A"State of power supply
power-ratingP"A"Rating of power supply: "N W"
temperatureP"A"N C< where N is an integer
* Refer to Table B-1.



If any component of a hierarchy path contains a period ( . ), you may not be able to use the findlist function. For example, if you search for the mount point /export/a0.test reported by the Config Reader via the path:
system.slot.board.io-unit.sbi.dma.esp.sd./export/a0.test
the node will not be found.  Instead, use:
system.slot.board.io-unit.sbi.dma.esp.sd.* to find this node.