Solaris Reference Manual for SMCC-Specific Software
この本のみを検索
PDF 文書ファイルをダウンロードする

NAME

prtdiag - print system diagnostic information

SYNOPSIS

/usr/platform/sun4d/sbin/prtdiag [ -v ] [ -l ]

AVAILABILITY

SUNWkvm.d
SUNWkvm.u

DESCRIPTION

prtdiag displays system configuration and diagnostic information.
The diagnostic information lists any failed Field Replaceable Units (FRUs) in the system.
prtdiag is supported only on sun4d and sun4u machines.
The interface, output, and location in the directory hierarchy for prtdiag are uncommitted and subject to change in future releases.

OPTIONS

The following options are supported:
-v
verbose mode.
On sun4d machines, displays the time of the most recent AC power failure, and the most recent system watchdog information. This information is useful only to depot repair and manufacturing for detailed diagnostics of FRUs.
On sun4u machines, displays various revision information, and (if applicable) environmental status, most recent AC power failure, and the most recent hardware fatal error information.
-l
log output.
If failures or errors exist in the system, output this information to syslogd(1M) only.

EXAMPLES

The example below displays sample output from a SPARCcenter 2000 machine.
example% /usr/platform/sun4d/sbin/prtdiag

System Configuration: Sun Microsystems sun4d SPARCcenter 2000
System clock frequency: 40 MHz
Memory size: 448Mb
Number of XDBuses: 2