| |
| ...Preface | xv |
Part 1 --System Information |
1. Product Description | 1-1 |
| ....1.1 Features | 1-2 |
| ....1.2 SPARCcluster 1000HA Server Configuration | 1-5 |
| ....1.3 SPARCcluster 2000HA Server Configuration | 1-6 |
| ....1.4 Internal Options | 1-7 |
| ......1.4.1 SPARCcluster 1000HA Server | 1-7 |
| ......1.4.2 SPARCcluster 2000HA Server | 1-7 |
| ......1.4.3 SPARCstorage Array Model 100 Series | 1-8 |
| ....1.5 External Options | 1-9 |
| ......1.5.1 SPARCcluster 1000HA Server | 1-9 |
| ......1.5.2 SPARCcluster 2000HA Server | 1-10 |
| ......1.5.3 SPARCstorage Array Model 100 Series | 1-10 |
Part 2 --Troubleshooting |
| |
2. Troubleshooting Overview | 2-1 |
| ....2.1 SPARCcluster Architecture | 2-1 |
| ....2.2 Maintenance Authorization | 2-1 |
| ....2.3 Troubleshooting a Remote Site | 2-1 |
| ....2.4 Troubleshooting Flow | 2-2 |
| ......2.4.1 Takeover | 2-2 |
| ......2.4.2 Switchover | 2-2 |
| ......2.4.3 Failures Where There is no Takeover | 2-2 |
| ....2.5 Fault Classes/Principal Assemblies | 2-4 |
| ....2.6 Error Messages/Symptoms | 2-5 |
| ....2.7 Device to Troubleshooting Cross Reference | 2-6 |
| ....2.8 Device Replacement Cross Reference | 2-7 |
3. Hardware Troubleshooting | 3-1 |
| ....3.1 Solaris Reconfiguration Reboots | 3-2 |
| ....3.2 SPARCstorage Array/Optical Connections Faults | 3-2 |
| ......3.2.1 Multi-disk Errors From Both Nodes on the Same |
| ...........SPARCstorage Array | 3-3 |
| ......3.2.2 Multiple Disk Errors or Disk Communication Error |
| ...........For One Node Only | 3-4 |
| ......3.2.3 SPARCstorage Array Fails to Communicate | 3-5 |
| ....3.3 Node Failures | 3-12 |
| ......3.3.1 System Board, Control Board, and Boot Disk | 3-12 |
| ......3.3.2 prtdiag Command | 3-13 |
| ......3.3.3 Using probe scsi Command | 3-15 |
| ....3.4 Network Failures | 3-17 |
| |
| ......3.4.1 Private Net Failure (SunFastEthernet) | 3-17 |
| ......3.4.2 Client Net Failure | 3-20 |
| ....3.5 Terminal Concentrator/Serial Connection Faults | 3-20 |
| ......3.5.1 System Indicators | 3-21 |
| ......3.5.2 Serial Connections | 3-22 |
| ......3.5.3 Intermittent Router Problems | 3-22 |
| ......3.5.4 Terminal Concentrator Flow Diagrams | 3-23 |
| ......3.5.5 Additional Troubleshooting Tips | 3-27 |
4. Software Troubleshooting | 4-1 |
| ....4.1 Software Faults | 4-2 |
| ......4.1.1 Operating System Failures | 4-2 |
| ......4.1.2 Solstice HA Failures | 4-2 |
| ......4.1.3 SPARCstorage Array Failures | 4-2 |
| ......4.1.4 Oracle Failures | 4-2 |
| ......4.1.5 NFS Failures | 4-2 |
5. Diagnostics | 5-1 |
| ....5.1 Failure Diagnosis and Confirmation of Component Repair |
| .......Using SunVTS/SunDiag | 5-1 |
| ....5.2 Verify HA Configuration using hacheck Command | 5-1 |
Part 3 --Preparing for Service |
6. Saftey and Tools Requirements | 6-1 |
| ....6.1 Safety Precautions | 6-1 |
| ....6.2 Symbols | 6-2 |
| ....6.3 System Precautions | 6-4 |
| |
| ....6.4 Tools Required | 6-5 |
7. Shutdown and Restart Procedures | 7-1 |
| ....7.1 SPARCcluster 1000HA Server | 7-2 |
| ......7.1.1 System Cabinet | 7-2 |
| ......7.1.2 Processor | 7-4 |
| ......7.1.3 SPARCstorage Array | 7-8 |
| ......7.1.4 Terminal Concentrator | 7-11 |
| ....7.2 SPARCcluster 2000HA Server | 7-11 |
| ......7.2.1 System Cabinet | 7-11 |
| ......7.2.2 Processor Shutdown/Startup | 7-17 |
| ......7.2.3 SPARCstorage Array | 7-19 |
| ......7.2.4 Boot Disks | 7-20 |
| ......7.2.5 Terminal Concentrator | 7-20 |
Part 4 --Subassembly Removal and Replacement |
8. Internal Access | 8-1 |
| ....8.1 SPARCserver 1000HA Server | 8-2 |
| ......8.1.1 Rear Screen Panel | 8-2 |
| ......8.1.2 Vented Front Panels | 8-3 |
| ....8.2 SPARCcenter 2000HA Server | 8-4 |
| ......8.2.1 Cabinet Panels | 8-4 |
| ......8.2.2 Hinged Door (System Cabinet Only) | 8-5 |
| ......8.2.3 Vented Front Panels | 8-5 |
| ......8.2.4 Rear Screen Panel | 8-6 |
| ......8.2.5 Side Panels | 8-7 |
| |
| ......8.2.6 Kick Panel | 8-8 |
| ......8.2.7 Stabilizer Bar | 8-9 |
9. Major Subassemblies | 9-1 |
| ....9.1 SPARCcluster 1000HA Server | 9-2 |
| ......9.1.1 System Board and Components | 9-2 |
| ......9.1.2 Boot Disks | 9-2 |
| ......9.1.3 SPARCstorage Array | 9-2 |
| ......9.1.4 Blower Assembly | 9-3 |
| ......9.1.5 Terminal Concentrator | 9-5 |
| ......9.1.6 Cabling | 9-7 |
| ....9.2 SPARCcluster 2000HA Server | 9-8 |
| ......9.2.1 System Board and Components | 9-8 |
| ......9.2.2 SPARCstorage Array | 9-8 |
| ......9.2.3 Boot Disks | 9-9 |
| ......9.2.4 Terminal Concentrator | 9-11 |
| ......9.2.5 Cabling | 9-12 |
Part 5 --Illustrated Parts Breakdown |
10. Illustrated Parts Breakdown | 10-1 |
| ...10.1 SPARCcluster 1000HA Server | 10-3 |
| ...10.2 SPARCcluster 2000HA Server | 10-5 |
Part 6 --Appendixes, Glossary, and Index |
A. Product Specifications | A-1 |
| ...A.1 Physical Specifications | A-1 |
| ......A.1.1 SPARCcluster 1000HA Server | A-2 |
| |
| ......A.1.2 SPARCcluster 2000 HA Server | A-3 |
| ...A.2 Electrical Specifications | A-4 |
| ......A.2.1 SPARCcluster 1000HA Server | A-4 |
| ......A.2.2 SPARCcluster 2000HA Server | A-5 |
| ...A.3 Environmental Specifications | A-6 |
B. Connector Pinouts and Cabling | B-1 |
| ....B.1 SPARCstorage Array Fiber Optic Cables | B-1 |
| ....B.2 Terminal Concentrator Ports | B-1 |
| ......B.2.1 RJ-45 Serial Port Connectors | B-1 |
| ......B.2.2 Public Ethernet Connector | B-3 |
| ....B.3 Private Net Cables (Short/Long) | B-4 |
C. SCSI Targeting | C-1 |
D. SPARCstorage Array Firmware and Device Driver Error |
| .......Messages | D-1 |
| ...D.1 Message Formats | D-1 |
| ...D.2 System Configuration Errors | D-2 |
| ......D.2.1 soc Driver | D-3 |
| ...D.3 Hardware Errors | D-4 |
| ...D.4 Informational Messages: | D-10 |
| ...D.5 Internal Software Errors | D-12 |
| ...Index | Index-1 |