Contained Within
Find More Documentation
Featured Support Resources
| Download this book in PDF
Checklist
1
- This chapter gives specific information and checklists to use when inventorying each type of SPARCcluster High Availability system.
-
1.1 SPARCcluster 1000 High Availability System-- Factory-Assembled
1.1.1 General Description
-
Table 1-1
| Device | Minimum | Maximum | Comment |
| SPARCserver 1000 systems (nodes) | 2 | 2 |
|
| System boards | 4 (2/chassis) | 8 (4/chassis) |
|
| Memory | 256 Mbyte (128
Mbyte/chassis) | 1.0 Gbyte (512
Mbyte /chassis) | Each node is equipped with an
identical amount of memory. |
| (TM) SunFastEthernet SBus cards | 4 (2 per node) | 4 (2 per node) |
| SPARCstorage Array 100 units | 3 | 3 | Each equipped with 2 FC/OM optical modules. |
| FC/S cards | 6 (3 per node) | 16 (8 per node) |
| FC/OM optical modules | 3 | 8 | One additional for each SPARCstorage array. |
| Terminal concentrator | 1 | 1 |
| Cable set | 1 |
|
| Expansion cabinet |
| 1 | To house 4th through 8th SPARCstorage array. |
1.1.2 Checklist
-
Table 1-2
| Category | Item | Quantity Planned | Quantity On Hand |
| Systems | SPARCserver 1000 systems
System boards
Memory |
|
|
| SBus cards | SunFastEthernet (SFE card)
FC/S card |
|
|
| Chassis | SPARCstorage Array 100 units |
|
|
-
Table 1-2 (Continued)
| Category | Item | Quantity Planned | Quantity On Hand |
| Terminal concentrator |
|
|
| Cables Expansion cabinet
| RS-232 serial cable, PN 530-2152 Ethernet cable, standard Sun private net cable, 1 meter, PN 530-2149 Sun private net cable, 5 meter, PN 530-2150 Optional fiber optic cable, 2 meter, PN 537-1004 Optional fiber optic cable, 15 meter, PN 537-1006
|
|
|
1.2 SPARCcluster 1000 High Availability System-- Customer-Assembled
1.2.1 General Description
-
Table 1-3
| Device | Minimum | Maximum | Comment |
| SPARCserver 1000 systems (nodes) | 2 | 2 |
|
| System boards | 4 (2/chassis) | 8 (4/chassis) |
|
| Memory | 256 Mbyte (128
Mbyte/chassis) | 1.0 Gbyte (512
Mbyte /chassis) | Each node is equipped with an
identical amount of memory. |
| SunFastEthernet SBus cards | 4 (2 per node) | 4 (2 per node) |
| SPARCstorage Array 100 units | 3 | 8 | Each equipped with 2 FC/OM optical modules. |
| FC/S cards | 6 (3 per node) | 16 (8 per node) |
| FC/OM optical modules | 3 | 8 | One additional for each SPARCstorage array. |
| Terminal concentrator | 1 | 1 |
-
Table 1-3 Requirements for SPARCcluster 1000 High Availability Configuration
-
Device Minimum Maximum Comment
Cable set 1
Rail set, consisting of a left and a right side rail5 (1 set per10 (1 set per
and one base plate to mount one chassis -- pluschassis) chassis)
associated mounting hardware, a label, power
cords and documentation
Expansion cabinet 1 To house 4th through 8th
SPARCstorage array.
1.2.2 Checklist
Table 1-4Checklist for SPARCcluster 1000 High Availability Model
Category Item Quantity Planned Quantity On Hand
Systems SPARCserver 1000 systems
System boards
Memory
SBus cards FC/S card
SunFastEthernet (SFE card)
Chassis SPARCstorage Array 100 units
Terminal concentrator
Cables RS-232 serial cable
Ethernet cable, standard
Sun private net cable, 1 meter, PN 530-2149
Sun private net cable, 5 meter, PN 530-2150
Optional fiber optic cable, 2 meter, PN 537-1004
Optional fiber optic cable, 15 meter, PN 537-1006
Rail kit Rail set, consisting of a left and a right side rail and one base
plate to mount one chassis -- plus associated mounting
hardware, a label, power cords, and documentation
Expansion
cabinet
|
1.3 SPARCcluster 2000 High Availability System -- Factory-Assembled
1.3.1 General Description
-
Table 1-5
| Device | Minimum | Maximum | Comment |
| System boards | 6 (3/cabinet) | 20 (10/cabinet) |
|
| Memory | 768 Mbyte (384
Mbyte/cabinet) | 10.0 Gbyte (5.0
Gbyte /cabinet) | Each node is equipped with an identical
amount of memory. |
| FSBE/S cards | 4 (2/cabinet) | 4 (2/cabinet) | In each node, one supports the the boot disks and one supports the SCSI panel. |
| SunFastEthernet SBus cards | 4 (2/cabinet) | 4 (2/cabinet) |
| SPARCstorage Array 100 units | 3 | 20 | Each equipped with 2 FC/OM optical modules. |
| FC/S card | 6 (3 per node) | 40 (20 per node) |
| FC/OM optical modules | 3 | 40 (20 per node) | One additional for each SPARCstorage array. |
| Disks (for booting)e | 2 | 2 |
| Terminal concentrator | 1 | 1 |
| Cable set | 1 |
|
| SCSI II cables | 2 |
| One connects to the boot disks, one connects to the SCSI tray. |
| SCSI II terminator | 2 |
| One each on the boot disk and SCSI tray SCSI OUT connector. |
| Expansion cabinet |
| 4 | To house 5th through 20th SPARCstorage array as appropriate. |
1.3.2 Checklist
-
Table 1-6
| Category | Item | Quantity Planned | Quantity On Hand |
| Systems | SPARCcenter 2000 systems
System boards
Memory |
|
|
| SBus cards | FC/S card
SunFastEthernet (SFE card)
FSBE/S card |
|
|
| Chassis | SPARCstorage Array 100 units
Disks (for booting)
Terminal concentrator |
|
|
| Cables Expansion cabinets
| SCSI II cables SCSI II terminator RS-232 serial cable Ethernet cable, standard Sun private net cable, 1 meter, PN 530-2149 Sun private net cable, 5 meter, PN 530-2150 Optional fiber optic cable, 2 meter, PN 537-1004 Optional fiber optic cable, 15 meter, PN 537-1006
|
|
|
1.4 SPARCcluster 2000 High Availability System -- Customer-Assembled
1.4.1 General Description
-
Table 1-7
| Device | Minimum | Maximum | Comment |
| System boards | 6 (3/cabinet) | 20 (10/cabinet) |
|
| FSBE/S cards | 4 (2/cabinet) | 4 (2/cabinet) | In each node, one supports the the boot disks and one supports the SCSI panel. |
| SunFastEthernet SBus cards | 4 (2/cabinet) | 4 (2/cabinet) |
| SPARCstorage Array 100 units | 3 | 20 | Each equipped with 2 FC/OM optical modules. |
| FC/S card | 6 (3 per node) | 40 (20 per node) |
| FC/OM optical modules | 3 | 40 (20 per node) | One additional for each SPARCstorage array. |
| Disks (for booting), 1 GByte | 2 | 2 |
| Terminal concentrator | 1 | 1 |
| Cable set | 1 |
|
| SCSI II cable | 4 (2/node) | 4 (2/node) | To connect boot disks and the SCSI panel. |
| SCSI II terminator | 4 (2/node) | 4 (2/node) | To terminate boot disks and the SCSI panel. |
| Rail set, consisting of a left and a right side rail and one base plate to mount one SPARCstorage array (chasssis) -- plus associated mounting hardware, a label, power cords and documentation | 3 sets (1/chassis) | 20 sets (1/chassis) |
| Expansion cabinet | 4 | To house 5th through 20th SPARCstorage array as appropriate. |
1.4.2 Checklist
-
Table 1-8
| Category | Item | Quantity Planned | Quantity On Hand |
| Systems | SPARCcenter 2000 systems
System boards
Memory |
|
|
| SBus cards | FC/S card
SunFastEthernet (SFE card)
FSBE/S card |
|
|
| Chassis | SPARCstorage Array 100 units
Disks (for booting)
Terminal concentrator |
|
|
| Cables Expansion cabinets